User's Manual

31 I 72
(spectrum). These values are used, in particular, for removing
background noise.
The frequency spectrum data enables the algorithm to differentiate
between leak noise and mechanical noises.
In addition, if there is a correlation at the same position near the
logger for more than one day, this will also increase the leak score.
The result is output as the Leak Score in a range from 0 to 100.
The settings for the display of a possible or probable leak are
made under Administration in Settings
Reference number of the displayed Logger
The Location field is a text field in which the location of the Logger,
e.g., the street and street number, can be entered
The smallest dB value measured during the last measurement.
Comments is a text field with entries on, e.g., permanent noise
sources
Logger
Location
Min. Noise