Data Sheet

REMOTE CONTROL
263
[:SOURce]:SAFEty:PRESet:TIME:PASS
Sets the buzzer sound continuous time when pass.
Parameter: <NRf>(0.2 ~ 999.9)
Example: SAFE:PRES:TIME:PASS 1
Sets the buzzer sound continuous time when pass to 1 sec.
[:SOURce]:SAFEty:PRESet:TIME:PASS?
Returns the buzzer sound continuous time when pass.
Return parameter: <NR3>
Example: SAFE:PRES:TIME:PASS?
> +1.000000E+00
The buzzer sound continuous time when pass is 1 sec.
[:SOURce]:SAFEty:PRESet:TIME:STEP
Sets the interval time between step and step.
Parameter: <NRf>(0.0 ~ 999.9) | KEY
Example: SAFE:PRES:TIME:STEP 0.5
Sets the interval time between step and step to 0.5sec.
[:SOURce]:SAFEty:PRESet:TIME:STEP?
Returns the interval time between step and step.
Return parameter: <NR3>
Example: SAFE:PRES:TIME:STEP?
> +5.000000E-01
The Interval time between step and step is 0.5sec.