Instructions

PSW Series User Manual
106
Bleeder Control
Bleeder control turns ON/OFF the bleeder
resistor. When set to AUTO the bleeder resistor
is automatically turned on when the output is
turned on and turned off when the output is
turned off. Bleeder resistors discharge the filter
capacitors after power is turned off as a safety
measure.
The AUTO setting is only applicable to
firmware version 1.59 or above.
F-09
0 = OFF, 1 = ON, 2 = AUTO
Buzzer ON/OFF
Turns the buzzer sound on or off. The buzzer is
associated with alarm sounds and keypad entry
sounds.
F-10
0 = OFF, 1 = ON
Measurement
Average Setting
Determines the level of smoothing for the
average setting.
Only available for firmware version 1.5 or
above.
F-17
0 = Low, 1 = Middle, 2 = High
Lock Mode
Determines the behavior of the Output key
when the panel lock is on.
Only available for firmware version 1.54 or
above.
F-19
0 = Panel lock: allow output off, 1 =
Panel lock: allow output on/off
USB/GPIB Settings
Front Panel USB
State
Displays the front panel USB-A port state. This
setting is not configurable.
F-20
0 = Absent, 1 = Mass Storage