Instructions

OPERATION
61
6. If CV Slew Rate Priority was chosen as the
operating mode, repeat steps 3~5 to set F-04
(Rising Voltage Slew Rate) and the F-05 (Falling
Voltage Slew Rate) and save.
F-04 / F-05
0.1V/s~60V/s (PSW 30-XX)
0.1V/s~160V/s (PSW 80-XX)
0.1V/s~320V/s (PSW 160-XX)
0.1V/s~500.0V/s (PSW 250-XX)
1V/s~1600V/s (PSW 800-XX)
7. Press the Function key again to exit
the configuration settings. The
function key light will turn off.
Function
8. Use the Current knob to set the
current limit (crossover point).
Current
9. Use the Voltage knob to set the
voltage.
Voltage
Note
Notice the Set key becomes illuminated when
setting the current or voltage. If the Voltage or
Current knobs are unresponsive, press the Set key
first.
10. Press the Output key. The Output
key becomes illuminated.
Output