Instructions

PSW Series User Manual
84
Analog Connector
Connection
To operate the power supplies in series, connect
the analog connectors on the master and slave
unit as shown in the diagram below.
Alternatively, the optional PSW-005 cable is
pre-configured for serial use.
2
12
17
20
21
Master unit
A COM16
OUTPUT ON STATUS21
ALM STATUS20
STATUS COM17
SHUTDOWN12
Slave Unit 1
25 SER SLV IN
20 ALM STATUS
12 SHUTDOWN
2 D COM
24 OUT OFF/ON CONT
2 D COM
24 20 12
17
25
2
16
17 STATUS COM
Series Output
Connection
Master unit
Load
+
-
Slave unit
Steps
1. Ensure the power is off on both power supplies.
2. Choose a master and slave unit.
3. Connect the analog connectors for the master
and slave unit as shown above.
4. Remove the output terminal cover
and the protection dummy plug
from the analog control connector.
Page 44