AEL-5000 Series AC & DC Electronic Load FEATURES CC, Linear CC, CR, CV, CP and AC Rectifier Load Mode Frequency Range : DC, 40~440Hz Turbo Mode for 2 Times the Current and Power of Electronic Load within 1 Second Eight Units Connected in Parallel up to 180kW for Single-phase and 540kW for Three-phase.
AC & DC Electronic Load AEL-5000 Series AEL-5002-350-18.75 AEL-5003-350-28 AEL-5004-350-37.5 AEL-5002-425-18.75 AEL-5003-425-28 AEL-5004-425-37.5 AEL-5003-480-18.75 AEL-5004-480-28 AEL-5006-350-56 AEL-5008-350-75 AEL-5006-425-56 AEL-5008-425-75 AEL-5012-350-112.5 AEL-5015-350-112.5 AEL-5019-350-112.5 AEL-5012-425-112.5 AEL-5015-425-112.5 AEL-5019-425-112.5 Power (W) AEL-5023-350-112.5 AEL-5023-425-112.5 Current(Ampere) MODEL Turbo OFF Turbo OFF Turbo ON Voltage(Volt) AEL-5002-350-18.
AC & DC Electronic Load FEATURES ● 4 digit V / A/W Meter,display the Voltage (Vrms, Vpeak, Vmax., Vmin)、Current (Irms, Ipeak, Imax., Imin.)、 Watt, Voltampere (VA)、Frequency、Crest Factor、Power Factor、Total Harmonic Distortion of Voltage (VTHD), Voltage Harmonic (VH)、Total Harmonic Distortion of Current (ITHD), Current Harmonic (IH) ● CC, Linear CC, CR, CV, CP and AC Rectifier Load mode ● Crest factor range : 1.414~5.
AC & DC Electronic Load POWER CURVE 3 AEL-5002-350-18.75 AEL-5003-350-28 AEL-5004-350-37.5 AEL-5002-425-18.75 AEL-5003-425-28 AEL-5004-425-37.5 AEL-5006-350-56 AEL-5008-350-75 AEL-5012-350-112.5 AEL-5015-350-112.5 AEL-5019-350-112.5 AEL-5023-350-112.5 AEL-5006-425-56 AEL-5008-425-75 AEL-5012-425-112.5 AEL-5015-425-112.5 AEL-5019-425-112.5 AEL-5023-425-112.5 AEL-5003-480-18.75 AEL-5004-480-28 Good Will Instrument Co., Ltd.
AC & DC Electronic Load COMPLETE AC AND DC LOAD MODES AEL-5000 Series Operating Modes AC Load DC Load PWM, Step, Square Wave Voltage Source Sine Wave Voltage Source Constant Current Mode Constant Current Mode Linear Constant Current Mode Linear Constant Current Mode Linear Constant Current Mode Constant Resistance Mode Constant Resistance Mode Constant Resistance Mode Constant Power Mode Constant Power Mode Constant Voltage Mode Constant Voltage Mode Rectifier Load Non-linear Mode Rectifi
AC & DC Electronic Load AC LOAD MODE CC Mode : In the constant current mode of AC Load, can be applied to sine wave voltage source, providing CF, PF test of linear load. V I CC mode CC mode, CF = 2 CC mode, CF = 5 CC mode, CF = +0.5 CC mode, CF = -0.5 Linear Constant Current Mode : Can be applied to sine wave and non-sine wave voltage source, as shown in the PWM inverter driver, step voltage source, and off-line UPS sine wave switch to square wave, square wave switch to sine wave.
AC & DC Electronic Load Supports the loading and unloading current angle control ; the loading and unloading current angle range of 0-359 degrees can be programmed to verify whether the Inverter output voltage transient response is stable during the actual electrical appliance is connected or turn ON / OFF randomly it can be used to verify the Overshoot / Undershoot response is within the desire range.
AC & DC Electronic Load I n r u s h C u rre n t te st a t b oot AC RECTIFIED LOAD SIMULATION MEET THE IEC62040-3 AND IEC61683 TEST SPECIFICATIONS AEL-5000 Series AC & DC electronic load AC rectified load mode is fully compliance with the IEC test specification requirements for the UPS, IEC 62040-3 UPS Efficiency Measurement Non-Linear and IEC 61683 Resistive Plus Non-Linear, respectively, AEL-5000 Series AC rectifier load mode uses CC + CR load mode and maintain current THD at 80%, to simulate the actual
AC & DC Electronic Load AEL-5000 LOAD VARIOUS TEST MODES The AEL-5000 Series AC & DC electronic load features built-in test modes for a variety of products. Including AC Load of UPS, Inverter, Fuse/Breaker, AC Power Source,and DC Load of Battery, Fuse/Breaker, DC Power Source etc..,as shown below.
AC & DC Electronic Load CURRENT PROTECTION COMPONENT TEST Current protection component includes Fuse, Circuit breakers and a new PTC Resettable fuse etc.., its function is when the circuit current exceeds the design of the rated value, that is, if the load exceeds the design of the current capacity, the circuit will be disconnected, in order to avoid overheating, even fire. Fuse is a one-time use of the protection components, Breaker and PTC can be reused.
AC & DC Electronic Load Turbo OFF, OCP Istep 3.75 A Istop 37.5A Test result screen Turbo OFF, OCP Istep 3.75 A Istop 37.5A Setting Turbo OFF, OCP Istep 3.75 A Istop 37.5A The actual test waveform Turbo ON, OCP Istep 7.5 A Istop 75A Test result screen Turbo ON, OCP Istep 7.5 A Istop 75.0A Setting Turbo ON, OCP Istep 7.5 A Istop 75.0A The actual test waveform Basically, Fuse test has Trip (Blown) and Non-Trip (no Blown) 2 types.
AC & DC Electronic Load BATTERY TEST FUNCTION AEL-5000 Series AC & DC electronic load has built-in new TYPE1 ~ TYPE3 battery discharge test, you can select the desired battery test mode, the test results can be directly displayed on the LCD display for battery AH capacity, the voltage value after discharge and the cumulative discharge time.
AC & DC Electronic Load GPIB, RS-232, USB or LAN Interface GPIB, RS-232, USB, LAN or Manual Master Slave 1 Slave2 Master Slave 1 Slave2 L1 L2 L3 GPIB, RS-232, USB, Support 1 master and up to 7 slaves operation. Maximum up to 8 units can be connected in parallel, total power of single-phase can up to 180 kW LAN or Manual Master Slave 1 L2 GPIB, RS-232, USB, Support 1 master and up to 7 slaves operation.
AC & DC Electronic Load PANEL INSTRUCTIONS 1 2 3 4 5 6 8 9 Operate function keys LCD Multi-function display 1 Four meters can display the voltage value at the same time the Voltage(Vrms, Vpeak, Vmax., Vmin)、Current (Irms, Ipeak, Imax., Imin.
AC & DC Electronic Load MODEL AEL-5002-350-18.75 SPECIFICATIONS AEL-5003-350-28 AEL-5004-350-37.5 AEL-5002-425-18.75 AEL-5003-425-28 0.15ms~999.99ms 0.15ms~999.99ms 0.1~9999.9Sec. 0.1~1.0Sec. 0.1~9999.9Sec. 0.1~1.0Sec. 0.1~10Sec. or Cont. 0.1~1Sec. 0.1~10Sec. or Cont. 0.1~1Sec. 0.1ms~100ms 0.1ms~100ms 0.01~0.5Sec. 0.01~0.5Sec. 0.01~9.99Sec. or Cont. 0.01~9.99Sec. or Cont.
AC & DC Electronic Load MODEL AEL-5006-350-56 SPECIFICATIONS AEL-5008-350-75 AEL-5012-350-112.5 AEL-5015-350-112.5 AEL-5019-350-112.5 AEL-5023-350-112.5 0.15ms~999.99ms 0.1~9999.9Sec. 0.1~1.0Sec. 0.1~10Sec. or Cont. 0.1~1Sec. 0.1ms~100ms 0.01~0.5Sec. 0.01~9.99Sec. or Cont.
AC & DC Electronic Load MODEL AEL-5006-425-56 SPECIFICATIONS AEL-5008-425-75 AEL-5012-425-112.5 AEL-5015-425-112.5 AEL-5019-425-112.5 AEL-5023-425-112.5 0.15ms~999.99ms 0.1~9999.9Sec. 0.1~1.0Sec. 0.1~10Sec. or Cont. 0.1~1Sec. 0.1ms~100ms 0.01~0.5Sec. 0.01~9.99Sec. or Cont.
AC & DC Electronic Load SPECIFICATIONS MODEL AEL-5003-480-18.75 AEL-5004-480-28 0.15ms~999.99ms 0.1~9999.9Sec. 0.1~1.0Sec. 0.1~10Sec. or Cont. 0.1~1Sec. HANDLES, U-shaped handle HANDIES, U-shaped ha(fixed to the bracket) (for AEL-5006/5008/5012/5015) 0.1ms~100ms 0.01~0.5Sec. 0.01~9.99Sec. or Cont.
AC & DC Electronic Load ORDERING INFORMATION ACCESSORIES : HD-DSUB 15 PIN Parallel wire GTL-246 GTL-248 GTL-250 USB Cable, USB 2.0, A-B Type, 1200mm GPIB Cable, Double Shielded, 2000mm GPIB Cable, Double Shielded, 600mm HANDLES, U-shaped handle(fixed to the bracket)(for AEL-5006/5008/5012/5015) PEL-029 HANDLES Rack Accessories(for AEL-5002/5003/5004) PEL-030 GPIB+RS-232 Card Note: * Regarding the product delivery date, please contact your regional sales representative.