MODULATION
129
Delay time
0s~655350nS
Default
0s
Burst Trigger Output
The Trig Out terminal on the rear panel can be used for burst or
sweep modes to output a rising edge TTL compatible trigger signal.
By default the trigger signal is rising edge. The trigger signal is
output at the start of each burst.
1. Press the Burst key.

2. Press F1 (N Cycle).
yl

3. Press F5 (TRIG set).
st

4. Press F5 (TRIG out).
out

5. Press F3 (ON/OFF) to toggle
Trigger out ON/OFF.


6. Select F1 (Rise) or F2 (Fall)
edge trigger.
s

~
all

When the internal trigger is selected, a square
wave with a 50% duty cycle is output at the
beginning of each burst.
Trig Out cannot be used with manual triggering
and will be disabled if manual triggering is set.
For manual triggering, a pulse is output (>1us)
from the Trig Out connector at the start of each
burst.