REMOTE INTERFACE
233
SOURce[1|2]:PM:STATe
Source Specific
Command
Turns PM Modulation on or off. By default PM
modulation is off.
Burst or sweep mode will be disabled if PM
modulation is enabled. As only one modulation is
allowed at any one time, other modulation modes
will be disabled when PM modulation is enabled.
SOURce[1|2]:PM:STATe {OFF|ON}
SOUR1:PM:STAT ON
Enables PM modulation
SOURce[1|2]:PM:STATe?
0
Disabled (OFF)
1
Enabled (ON)
SOUR1:PM:STAT?
1
PM modulation is currently enabled.
SOURce[1|2]:PM:SOURce
Source Specific
Command
Sets or queries the PM source as internal or
external. Internal is the default source.
If an external PM source is selected, the phase
modulation is controlled by the MOD INPUT
terminal on the rear panel.
SOURce[1|2]:PM:SOURce {INTernal|EXTernal}
SOUR1:PM:SOUR EXT
Sets the PM source to external.
SOURce[1|2]:PM:SOURce?
INT
Internal
EXT
External