User Manual
GSB-01/GSB-02 Series User Manual
48
MANU Test Results
Background
If the test is allowed to run to completion (the
test is not stopped or a protection setting is not
tripped) then the tester will judge the test(s) as
either PASS or FAIL.
The pass/fail result of the test(s) is shown on
the safety tester display and the scanner box(s).
Please note that when multiple DUTs are tested
simultaneously and a fail result is produced, it
indicates that at least one DUT failed the test. It
doesn’t indicate which of the DUTs passed or
failed. Each DUT would have to be tested
separately to determine that.
Note
The test will be judged PASS when:
The HI SET and LO SET limits have not been
tripped during the test time.
The test will be judged FAIL when:
Either the HI SET or LO SET limit has been
tripped during the test time.
A protection setting has been tripped during
the test time.
Test may not finish if the scanner boxes are not
properly connected.