Datasheet

E16
E15
Made to Measure. Good Will Instrument Co., Ltd.
FEATURES
LCR-821 (12Hz~200kHz)
12Hz~200kHz (LCR-821)
12Hz~100kHz (LCR-819/829)
12Hz~10kHz (LCR-817/827)
100Hz~2kHz (LCR-816/826)
* Test Frequency:
* 0.05~0.1% Measurement Accuracy
* 100 Sets Memory for Save/Recall of Settings
* R/Q, C/D, C/R, L/Q Test Modes for all Models;
Z/ , L/R for LCR-821 Only
* Absolute Value, Value, and % Measurement
Display
* 240 x 128 dot Matrix LCD Display
* Condition and Test ResultDisplays
Simultaneously
* Interface : RS-232C (LCR-821/819/817/816)
Handler (LCR-829/827/826)
SPECIFICATIONS
TEST FREQUENCY
BASIC ACCURACY
TEST SPEED
TEST SIGNAL LEVELS
DC BIAS
DISPLAY RANGE
TEST MODE
EQUIVALENT CIRCUIT
MEMORY
AVERAGE
TEST SPEED MODE
DISPLAY MODE
DISPLAY
INTERFACE
POWER SOURCE
DIMENSIONS & WEIGHT
0.05% for basic accuracy for LCR-821/819/817
12Hz ~ 200kHz (504 steps) for LCR-821
5mV ~ 1.275Vrms ( 5mV/step ) for LCR-821/819/829/817/827
0.1V ~ 1.275Vrms ( 5mV/step )for LCR-816/826
R/Q , C/D, C/R, L/Q
Z/ , L/R for LCR-821 only
Parallel or s selectableeries
100 memory blocks total
1 to 255 times
SLOW, MEDIUM and FAST
Value, , %
240x128 dot matrix C.C.F.L back light LCD
Standard Interface : RS-232C for LCR-821
2V
0 ~ 35V for LCR-821; 0 ~ 30V for LCR-819/829/817/827/816/826
Internal
External
AC 100V ~ 240V , 47 ~ 63/400Hz
322 (W) x 149 (H) x 433 (D)mm, Approx. 5.5kg
Resistance
Capacitance
Inductance
Quality Factor
Dissipation Factor
Impedance
Phase Angle ( Degree )
Line Voltage Range
0 .00001 ~ 99999k
0.00001pF ~ 99999 F
0.00001mH ~ 99999H
0.0001 ~ 9999
0.0001 ~ 9999
0.00001 ~ 99999k for LCR-821
-180.00 ~ 180.00 for LCR-821
R
C
L
Q
D
Z
HIGH PRECISION LCR METER
LCR-817/827 (12Hz~10kHz)
LCR-819/829 (12Hz~100kHz)
0.1% for basic accuracy for LCR-829/827/826/816
68ms for LCR-821/819/817/816, 34ms for LCR-829/827/826
12Hz ~ 100kHz(503 steps) for LCR-819/829
12Hz ~ 10kHz(489 steps) for LCR-817/827
100Hz ~2kHz (245 steps) for LCR-816/826
Standard Interface : Handler Interface for LCR-829/827/826
Optional : RS-232C Interface for LCR-819/817/816
(Including LCR-Viewer Software)
(factory installed)
LCR-816/826(100Hz~2kHz)
12Hz~200kHz
(504 steps)
12Hz~100kHz
(503 steps)
240 x 128 dot matrix CCFL back light LCD
100 memory blocks totally
0.05%
2V
0 ~35V
Std.
Std. Std.Std.
Opt. Opt. Opt.
2V
0 ~30V
2V
0 ~30V
2V
0 ~30V
R/Q, C/D, C/R
L/Q, Z/ , L/R
R/Q, C/D, C/R,L/Q R/Q, C/D, C/R,L/Q R/Q, C/D, C/R,L/Q
0.05% 0.1% 0.05% 0.1% 0.1%
12Hz~10kHz
(489 steps)
100Hz~2kHz
(245 steps)
Test Frequency
Display
Memory
Basic Accuracy
Test Mode
DC BIAS
Interface
Internal
External
RS-232
Handler
MODEL
LCR-821 LCR-819 LCR-829 LCR-817 LCR-827 LCR-816 LCR-826
LCR-800 SERIES SELECTION GUIDE
Handler
BASIC T & M INSTRUMENTS
BASIC T & M INSTRUMENTS
LCR-821
LCR-821 Rear Panel
LCR-829 Rear Panel
LCR-819 Rear Panel
LCR-05LCR-06A
Patent:185538
Description:
Test fixture for measurement
of both axial and vertical
lead components
Frequency: DC to 1MHz
Max. Voltage: +/- 35V
Description:
Kelvin clip test leads.
Frequency: DC to 1MHz
Max. Voltage: +/- 35V
LCR-07
LCR-08
Patent:188540
Description:
Test leads for conventional
component measurement.
It is especially useful for high
impedance measurement.
(With alligator clips)
Two-wire measurement;
apply to low C or high R.
Frequency: DC to 1MHz
Max. Voltage: +/- 35V
Description:
SMD / clip tweezers
Frequency: DC to 1MHz
Max. Voltage: +/- 35V
LCR-09
Patent:186171
Description:
SMD / chip test fixture
Frequency: DC to 1MHz
Max. Voltage: +/- 35V
LCR-13
Patent:186171
Description:
SMD / chip test fixture
Frequency: DC to 1MHz
Max. Voltage: +/- 35V
Size range from 0603 to 1812 Size range from 0201 to 0805
The LCR-800 Series are high-end digital LCR meters for component/material measurements, applicable
to various R&D activities and assembly lines. The large 240 x 128 dot matrix LCD display provides
ampleroom for two measurement items and setup parameters allowing you to grasp measurement
results quickly. All test modes are able to measure supplementary factors such as, R/Q, C/D, C/R, and
L/Q. The LCR-821 also contains precise resistance measurements as a combination of absolute value
and phase angle. 100 sets of measurement setup memory allow sharing a single unit among multiple
testing conditions or sites. For a better viewing experience with a standard PC monitor, proprietary
Windows based software is accessible via the RS-232C terminal. The handler interface is also a
standard feature for LCR-826/827/829.
ACCESSORIES :
User manual x 1, Power cord x1, LCR-06A x 1
LCR-821
200kHz High Precision LCR Meter with RS-232 Interface
LCR-05 Test Fixture for Axial & Radial Leaded Components
Opt.01 RS-232C Interface ( Factory Installed )
LCR-06A Kelvin Clip Test Lead
LCR-07 Test Fixture, Two-Wire with Alligator Clips
LCR-08 Test Fixture(Tweezers) for SMD/Chip Components
LCR-09 Test Fixture for SMD/Chip Components
LCR-13 Test Fixture for SMD/Chip Components
GRA-402 Rack Adapter Panel, Rack Mounting (19", 4U)
GTL-232 RS232C Cable, 9-pin Female to 9-pin, null Modem for Computer
LCR-819
LCR-829
LCR-817
LCR-827
100kHz High Precision LCR Meter
100kHz High Precision LCR Meter with Handler Interface
10kHz High Precision LCR Meter
10kHz High Precision LCR Meter with Handler Interface
LCR-816
2kHz High Precision LCR Meter
LCR-826 2kHz High Precision LCR Meter with Handler Interface
Instrument Cart
GTC-002
Instrument Cart
GTC-001
ORDERING INFORMATION
OPTION
OPTIONAL ACCESSORIES
FREE DOWNLOAD
PC Software
LCR-Viewer
(**)
(*):Basic accuracy varies with the speed, frequency, AC signal level and impedance of the DUT.
(*)
(**):Display range refers to the range of measurement values that can be displayed on the screen.
Please see the LCR-800 user manual for the effective measurement ranges.

Summary of content (2 pages)