Single Load Connections
Dual Channel
Load Module
Connection
A dual channel load module can be used to sink
two loads concurrently.
Single Channel
Load Module
Connection
On a single channel load module, the left terminals
are both negative (-), whilst the right terminals are
both positive (+). Note this also applies to the
voltage sense terminals.
CAUTION
For loads exceeding 40A, both positive and both
negative terminals must be used in parallel.