User Guide

PEL-3000 Programmable DC Electronic Load
Product Appearance :
PEL-3021 / PEL-3041 PEL-3111 PEL-3211
Module Specifications
Model
Operating Voltage (DC)
Current
Power
PEL-3021
1.5V ~ 150V
35A
175W
PEL-3041
1.5V ~ 150V
70A
350W
PEL-3111
1.5V ~ 150V
210A
1050W
Booster Model
Operating Voltage (DC)
Current
Power
PEL-3211
1.5V ~ 150V
420A
2100W
Product Features and Customers Benefits :
Features
Advantages
Customers Benefits
Sequence Function
Via sequence editing function,
system or single unit users can edit
sink current condition of arbitrary
waveforms from the memory
function on the panel without
connecting with a computer.
Rapid editing of any sink current
conditions to save users cost of
system development.
Parallel function
(Max: 9,450W)
Via same model units in parallel,
the capacity of current and power
can be increased to meet the
demand of higher power
requirements. The maximum
power is 9,450W.
Users can procure master or booster
for parallel usage according to power
requirements that allows users to
flexibly spend expenditure in the
procurement process and enhance
equipment utilization efficiency.
Adjustable protective
points
Adjust protective points according
to test requirements.
Increase safety of DUT to reduce
loss.
Adjustable Slew Rate, the
maximum of 16A/us
Faster Slew Rate satisfies the
tests of high-speed power
products
Capable of conducting tests of higher
performance products
Soft Start
Reduce current change during
sudden load activation which
causes abnormal situation of the
voltage drop. During the
activation, load current follows the
set slew rate variation that will not
affect the overall test speed.
Increase test reliability during sudden
load activation when high Slew Rate
is in operation.
Load current
measurement
Electronic load directly provides
proportional load current
waveforms via the BNC connector.
Users can observe load current
waveforms without using a current
probe.
External voltage control
Directly control electronic load
operation and monitor load current
via external voltage.
Applicable to analog voltage control
situation.
Input voltage monitoring
GO/NO GO function
When input voltage exceeds the
set range, NG warning signal will
be shown on the display screen.
Increase the stability of test system
when encountering abnormal voltage
situation.
Commands are
compatible with
Kikusui PLZ-4W model.
Users can absolutely replace
PLZ-4W model with PEL-3000*.
Save time and cost of program
modification for users.
99 Washington Street
Melrose, MA 02176
Phone 781-665-1400
Toll Free 1-800-517-8431
Visit us at www.TestEquipmentDepot.com

Summary of content (1 pages)