User Manual

APPENDIX
157
PSB-2400L (Part 1/2)
Item
Single
Parallel
2400L
2400L x 2
2400L x 3
2400L + 2800L
2400L x 4
400W
800W
1200W
1600W
Voltage Setting
SLOW
10mV
FAST
1V
Range
0V to 82V
Min. display digit
10mV
Current Setting
SLOW
10mA
100mA
90mA
80mA
FAST
1A
10A
9A
8A
Range
0A-41A
0A-82A
0A-123A
0A-164A
Min. display digit
10mA
100mA
Power Setting
SLOW
10W
100W
FAST
100W
1000W
Range
10W-410W
20W-820W
30W-1230W
40W-1640W
Min. display digit
1W
OVP Setting
SLOW
100mV
FAST
10V
Range
1V-84V
Min. display digit
10mV
OCP Setting
SLOW
100mA
200mA
300mA
400mA
FAST
10A
20A
30A
40A
Range
1A-42A
2A-84A
3A-126A
4A-168A
Min. display digit
10mA
100mA
For parallel connections, the smallest value that can be displayed (Min. display digit) for
current is 100mA. When some model combinations are used in parallel, the actual current
setting resolution may be different to the display resolution. In this situation the display
may not update with only one click of the encoder.