Instruction Manual
PSM SERIES PROGRAMMABLE POWER SUPPLY
PROGRAMMER MANUAL
⎯ 29 ⎯
0-15V/7A Range 0-30V/4A Range
Programming Range 0V to15.45V 0V to 30.9V
MAX Value 15.45V 30.9V
MIN Value 0V 0V
DEFault Value 0V 0V
*RST Value 0V
MAX Ovp Value 32V
Voltage
MIN Ovp Value 0V
Programming Range 0A to 7.21A 0A to 4.12A
MAX Value 7.21A 4.12A
MIN Value 0A 0A
DEFault Value 7A 4A
*RST Value 7A
MAX Ocp Value 7.7A
Current
MIN Ocp Value 0A
Table1-2. PSM-3004 Programming Ranges
0-30V/6A Range 0-60V/3A Range
Programming Range 0V to 30.9V 0V to 61.8V
MAX Value 30.9V 61.8V
MIN Value 0V 0V
DEFault Value 0V 0V
*RST Value 0V
MAX Ovp Value 65V
Voltage
MIN Ovp Value 0V
Programming Range 0A to 6.18A 0A to 3.4A
MAX Value 6.18A 3.4A
MIN Value 0A 0A
DEFault Value 6A 3A
*RST Value 6A
MAX Ocp Value 6.6A
Current
MIN Ocp Value 0A
Table1-3. PSM-6003 Programming Ranges
PSM SERIES PROGRAMMABLE POWER SUPPLY
PROGRAMMER MANUAL
⎯ 30 ⎯
:CURRent
Function:
Set the output current value.
Syntax:
:CURRent {<current>|MIN|MAX|UP|DOWN}
1) <current> The range is from 0.0000 through 20.6000(PSM-2010
Please refer to Table1-1, Table1-2 and Table1-3.
2) MIN is for 0.0000 while MAX for 20.6000(PSM-2010). Please refer to
Table1-1, Table1-2 and Table1-3.
3) Up is for the current with one value increasing while down for the
current with one value decreasing. The value is set by the command of
CURRent:STEP.
Examples:
:CURRent 2.0 sets the current limit to 2.0000 amps(PSM-2010).
:CURRent MAX sets the current limit to 20.6000(PSM-2010) amps.
:CURRent:STEP 0.1;CURRent UP is for Current to increase 0.1 amps.
:CURRent?
Function:
Query the output current value.
Syntax:
:CURRent? [MIN|MAX]
Returns:
Scientific mark