Information
PSU-HV Series DC Power Supply New Product Announcement - 13
Trigger control (Trigger input/Trigger output)
PSU provides users with complete trigger input
and trigger output functions so as to flexibly
control PSU. Each function is elaborated as follows:
Trigger Input function:
①. Allow users to set the effective pulse width
from 0~ 60ms for trigger input (0: the LOW
or HIGH signal of DC level for trigger input)
②. Receive trigger input to control PSU output
or to output preset voltage and current.
③. Receive trigger input to upload preset
memory parameters.
Trigger Output function:
①. Allow users to set the effective pulse width
from 0~ 60ms for trigger output (0: the LOW
or HIGH signal of DC level for trigger output)
②. Set LOW or HIGH for output DC level
③. PSU produces trigger output signal when
setting output or changing preset value or
uploading preset memory parameters.
OVP,OCP and UVL
Setting range
PSU Series
OCP OVP UVL
6-200 5 ~ 220 0.6 ~ 6.6 0 ~ 6.3
12.5-120 5 ~ 132
1.25 ~ 13.75
0 ~ 13.12
20-76 5 ~ 83.6 2 ~ 22 0 ~ 21
40-38 3.8 ~ 41.8 4 ~ 44 0 ~ 42
60-25 2.5 ~ 27.5 5 ~ 66 0 ~ 63
100-15 1.5 ~ 16.5 5 ~ 110 0 ~ 105
150-10 1 ~ 11 5 ~ 165 0 ~ 157.5
300-5 0.5 ~ 5.5 5 ~ 330 0 ~ 315
400-3.8 0.38 ~ 4.18
5 ~ 440 0 ~ 420
600-2.6 0.26 ~ 2.86
5 ~ 660 0 ~ 630
Once the voltage or current output exceeds the
preset level of OVP or OCP, PSU will shut down
output to protect DUT.UVL is for users to set the
minimum output voltage from the output
terminal.