Reset to Factory Default Settings
Background
The F-88 configuration setting allows the PSU
to be reset back to the factory default settings.
See page 183 for the default factory settings.
Steps
1. Press the Function key. The
Function key will light up.
Function
2. The display should show F-01 on the top and
the configuration setting for F-01 on the
bottom.
VOLTAGE CURRENT
VSR LAN RMT ERR DLY ALM ISR M 1 M 2 M 3 RUN
C V C C
V A
3. Rotate the Voltage knob to change
the F setting to F-88 (Factory Set
Value).
Voltage
4. Use the Current knob to set the
F-88 setting to 1 (Return to factory
default settings).
Current
5. Press the Voltage knob to confirm.
ConF will be displayed when it is
configuring.
Voltage
VOLTAGE CURRENT
VSR LAN RMT ERR DLY ALM ISR M 1 M 2 M 3 RUN
C V C C
V A
6. Press the Function key again to
exit. The Function key light will
turn off.