User manual

PSU Series User Manual
98
CC Control
F-91
0 = Control by Local
1 = Control by External Voltage
2 = Control by External Resistor -
Rising
3 = Control by External Resistor -
Falling
4 = Control by Isolated Board
Output Status when
Power ON
F-92
0 = Safe Mode (Always OFF),
1 = Force Mode (Always ON),
2 = Auto Mode (Status before last
time power OFF)
Master/Slave
Configuration
F-93
0 = Independent
1 = Master with 1 slave in parallel
2 = Master with 2 slaves in parallel
3 = Master with 3 slaves in parallel
4 = Slave (parallel)
External Output Logic
F-94
0 = High ON, 1 = Low ON
Monitor Voltage Select
F-96
0 = 5V , 1 = 10V
Control Range
F-97
0 = 5V [5k], 1 = 10V [10k]
External Output Control
Function
F-98
0 = OFF, 1 = ON
Special Function Settings*
Calibration
F-00
0000 ~ 9999
*Note
Power On Configuration settings can only be set
during power up. They can, however, be viewed
under normal operation.