ADJUSTABLE SLEW RATE
TRIGGER CONTROL (TRIGGER INPUT/TRIGGER OUTPUT)
PSU-series provides users with complete trigger input and trigger output functions so as to flexibly control PSU-series.
Each function is elaborated as follows.
Adjustable Voltage Slew Rate
Trigger Output function :
1. Allow users to set the effective pulse width from 0~60ms for
trigger output (0: the LOW or HIGH signal of DC level for
trigger output)
2. Set LOW or HIGH for output DC level
3. PSU produces trigger output signal when setting output or
changing preset value or uploading preset memory parameters.
Trigger Input function :
1. Allow users to set the effective pulse width from 0~60ms for
trigger input (0: the LOW or HIGH signal of DC level for trigger input)
2. Receive trigger input to control PSU-series output or to output
preset voltage and current.
3. Receive trigger input to upload preset memory parameters.
VOLTAGE SLEW RATE
CURRENT SLEW RATE
Once the voltage or current output exceeds the preset
level of OVP or OCP, PSU will shut down output to protect
DUT.UVL is for users to set the minimum output voltage
from the output terminal.
OVP OCP AND UVL,
The PSU series can adjust slew rate for current and voltage.
Via setting the rise and fall time of voltage and current,
users can verify DUT's characteristics during voltage and
current variation. Additionally, slew rate adjustment can
mitigate voltage shift to effectively prevent DUT from being
damaged by inrush current. This function is ideal for tests
such as capacitive load and motor.