Datasheet

www.gwinstek.com
www.facebook.com/GWInstek
SU-SeriesGD1BH
PSU 6-200
PSU 12.5-120
PSU 20-76
PSU 40-38
PSU 60-25
Driver
LabView Driver
FREE DOWNLOAD
CD-ROM x 1(User Manual, Programming Manual), Output terminal cover x 1,
Analog connector plug kit x 1, ,Output terminal M8 bolt set(6V~60V model)
Input terminal cover x 1,1U Handle(RoHS),1U Bracket(LEFT, RoHS),1U Bracket
(RIGHT,RoHS),Power Cord(10A) x 1
GTL-246
USB Cable, USB 2.0A-B Type Cable, 4P
PSU-01B
Bus bar for 2 units in parallel connection
PSU-01C
Cable for 2 units in parallel connection
PSU-02B
Bus bar for 3 units in parallel connection
PSU-02C
Cable for 3 units in parallel connection
PSU-03B
Bus bar for 4 units in parallel connection
PSU-03C
Cable for 4 units in parallel connection
PSU-232
RS232 Cable with DB9 connector kit
PSU-485
RS485 Cable with DB9 connector kit
GRM-001
Slide bracket 2pcs/set ,PSU option
PSU-GPIB
GPIB Interface card (factory option)
PSU-ISO-I
Isolate current remote control card(factory option)
PSU-ISO-V
Isolate voltage remote control card(factory option)
GPW-001
UL/CSA power cord 3m ,PSU option
GPW-002
VDE power cord 3m ,PSU option
GPW-003
PSE power cord 3m ,PSU option
1200W
1500W
1520W
1520W
1500W
PSU-01A
PSU-02A
PSU-03A
Joins a vertical stack of 2 PSU units together. 2U-sized handles x2, joining plates x2
Joins a vertical stack of 3 PSU units together. 3U-sized handles x2, joining plates x2
Joins a vertical stack of 4 PSU units together. 4U-sized handles x2, joining plates x2
*1. Minimum voltage is guaranteed to maximum 0.2% of the rated output voltage.
*2. Minimum current is guaranteed to maximum 0.4% of the rated output current.
*3. At 85~132Vac or 170~265Vac, constant load.
*4. From No-load to Full-load, constant input voltage.
Measured at the sensing point in Remote Sense.
*5. Measure with JEITA RC-9131B (1:1) probe.
*6. Measurement frequency bandwidth is 10Hz~20MHz.
*7. Measurement frequency bandwidth is 5Hz~1MHz.
Note :
1.5ms
80ms
3mV 6.25mV 10mV 20mV 30mV 50mV 75mV 150mV 200mV 300mV
10ms
0.2mV 0.4mV 0.7mV 1.3mV 2mV 3.4mV 5.2mV 10.2mV 13.6mV 20.4mV
80ms
200mA 120mA 76mA 38mA 25mA 15mA 10mA 5mA 3.8mA 2.6mA
500ms
6mA 4mA 2.5mA 1.2mA 0.8mA 0.5mA 0.34mA 0.19mA 0.13mA 0.09mA
6mV 12.5mV 20mV 40mV 60mV 100mV 150mV 300mV 400mV 600mV
0.2mV 0.4mV 0.7mV 1.3mV 2mV 3.4mV 5.2mV 10.2mV 13.6mV 20.4mV
400mA 240mA 152mA 76mA 50mA 30mA 20mA 10mA 7.6mA 5.2mA
6mA
06 66V.~. 1.25 13.75V~ 2 22V~ 4 44V~
5 66V~
5 110V~ 5 165V~ 5 330V~ 5 440V~ 5 660V~
60mV 125mV 200mV 400mV 600mV 1000mV 1500mV 3000mV 4000mV 6000mV
4000mA 2400mA 1520mA 760mA 500mA 300mA 200mA 100mA 76mA 52mA
5 220A~ 5 132A~ 5 83.6A~ 3.8 41.8A~ 2.5 27.5A~ 1.5 16.5A~ 1 11A~ 0.5 5.5A~
0.38 4.18A~
0.26 2.86A~
063V~.
Turn the output off.
Turn the output off.
Turn the output off.
Turn the output off.
Over power limit
Approx. 105% of rated output power
TypeA: Host, TypeB: Slave, Speed: 1.1/2.0, USB Class: CDC(Communications Device Class)
MAC Address, DNS IP Address, User Password, Gateway IP Address, Instrument IP Address, Subnet Mask
Complies with the EIA232D / EIA485 Specifications
SCPI - 1993, IEEE 488.2 compliant interface
Using 0-5V or 0-10V signals for programming and measurement
Using 4-20mA current signals for programming and measurement
0 C 50 C°~ °
°~ °-25 C 70 C
~20% 85% RH; No condensation
90% RH or less; No condensation
Maximum 2000m
100Vac to 240Vac, 50Hz to 60Hz, single phase
85Vac ~ 265Vac
47Hz ~ 63Hz
21/11
Less than 50A
2000VA
0.99/0.98
20ms or greater
423 W × 43.6 H × 447.2 D mm, Approx. 8.7kg() () ()
0 13.12V~ 0 21V~ 0 42V~ 0 63V~ 0 105V~ 0 157.5V~ 0 315V~ 0 420V~ 0 630V~
100ppm/ after a 30 minute warm-up
1V
77/79
1V
82/85
1V
83/86
2V
84/87
3V
84/87
5V
84/87
5V
84/87
5V
84/87
5V
84/87
5V
84/87
4mA 2.5mA 1.2mA 0.8mA 0.5mA 0.34mA 0.19mA 0.13mA 0.09mA
1ms
80ms
50ms
80ms
700ms
1ms
80ms
50ms
80ms
800ms
1ms
80ms
80ms
80ms
1000ms
1ms
80ms
80ms
80ms
1100ms
1ms
150ms
150ms
150ms
1500ms
2ms
150ms
150ms
150ms
2000ms
2ms
150ms
150ms
150ms
2500ms
2ms
200ms
200ms
200ms
3000ms
2ms
250ms
250ms
250ms
4000ms
0.05%+
0.1%+
0.2%+
0.2%+
Setting Range
Setting Accuracy
Setting Range
Setting Accuracy
Setting Range
Operation
Operation
Operation
Operation
Operation
Value (Fixed)
Rated load
No load
Rated load
No load
USB
LAN
RS-232 / RS-485
GPIB (Factory Option)
PSU 6-200
PSU 12.5-120
PSU 20-76
PSU 40-38
PSU 60-25
PSU 100-15
PSU 150-10
PSU 300-5
PSU 400-3.8
PSU 600-2.6
SPECIFICATIONS
100Vac/200Vac(A)
100Vac/200Vac
(%)
100Vac/200Vac
*8. From 10%~90% of rated output voltage, with rated resistive load.
*9. From 90%~10% of rated output voltage, with rated resistive load.
*10. Time for output voltage to recover within 0.5% of its rated
output for a load change from 10~90% of its rated output
current. Voltage set point from 10%~100% of rated output.
*11. For load voltage change, equal to the unit voltage rating,
constant input voltage.
*12. For 6V model the ripple is measured at 2~6V output voltage and full
output current. For other models, the ripple is measured at 10~100%
output voltage and full output current.
13. At rated output power.*
No.7-1, Jhongsing Road, Tucheng Dist., New Taipei City 236, Taiwan
GOOD WILL INSTRUMENT CO., LTD.
Global Headquarters
TF+886-2-2268-0389 +886-2-2268-0639
E-mail: marketing@goodwill.com.tw
Simply Reliable
Specifications subject to change without notice.
ORDERING INFORMATION
SPECIFICATIONS
ACCESSORIES
OPTIONAL ACCESSORIES
Programmable Switching DC Power Supply
Programmable Switching DC Power Supply
Programmable Switching DC Power Supply
Programmable Switching DC Power Supply
Programmable Switching DC Power Supply
Programmable Switching DC Power Supply
Programmable Switching DC Power Supply
Programmable Switching DC Power Supply
Programmable Switching DC Power Supply
Programmable Switching DC Power Supply
MODEL
TRANSIENT RESPONSE TIME 10(* )
Transient Response Time
OUTPUT RESPONSE TIME
Rise Time(*8)
Fall Time(*9)
PROGRAMMING AND MEASUREMENTS (RS-232/485, USB, LAN, GPIB)
Output Voltage Programming Accuracy
Output Current Programming Accuracy
Output Voltage Programming Resolution
Output Current Programming Resolution
Output Voltage Measurement Accuracy
Output Current Measurement Accuracy
Output Voltage Measurement Resolution
Output Current Measurement Resolution
TEMPERATURE COEFFICIENCE
Voltage & Current
REMOTE SENSE COMPENSATION VOLTAGE SINGLE WIRE()
Voltage
PROTECTION FUNCTION
Over Voltage Protection(OVP)
Over Current Protection(OCP)
Under Voltage Limit(UVL)
Over Temperature Protection(OHP)
Incorrect Sensing Connection Protection(SENSE)
Low AC Input Protection (AC-FAIL)
Shutdown (SD)
Power Limit (POWER LIMIT)
INTERFACE CAPABILITIES
ISOLATED ANALOG CONTROL INTERFACE (FACTORY OPTION)
Voltage Control
Current Control
ENVIRONMENTAL CONDITIONS
Operating Temperature
Storage Temperature
Operating Humidity
Storage Humidity
Altitude
INPUT CHARACTERISTICS
Nominal Input Rating
Input Voltage Range
Input Frequency Range
Maximum Input Current
Inrush Current
Maximum Input Power
Power Factor
Efficiency (*13)
Hold-up Time
DIMENSIONS & WEIGHT