User Manual

GETTING STARTED
19
Rising current slew rate
F-06
0.01A/s~72.00A/s (PSW 30-36)
0.1A/s~144.0A/s (PSW 30-72)
0.1A/s~216.0A/s (PSW 30-108)
0.01A/s~27.00A/s (PSW 80-13.5)
0.01A/s~54.00A/s (PSW 80-27)
0.01A/s~81.00A/s (PSW 80-40.5)
Falling current slew rate
F-07
0.01A/s~72.00A/s (PSW 30-36)
0.1A/s~144.0A/s (PSW 30-72)
0.1A/s~216.0A/s (PSW 30-108)
0.01A/s~27.00A/s (PSW 80-13.5)
0.01A/s~54.00A/s (PSW 80-27)
0.01A/s~81.00A/s (PSW 80-40.5)
Internal resistance
setting
F-08
0.000~0.833 (PSW 30-36)
0.000~0.417 (PSW 30-72)
0.000~0.278 (PSW 30-108)
0.000~5.926 (PSW 80-13.5)
0.000~2.963 (PSW 80-27)
0.000~1.975 (PSW 80-40.5)
Bleeder circuit control
F-09
0 = OFF, 1 = ON
Buzzer ON/OFF control
F-10
0 = ON, 1 = OFF
USB/GPIB settings
Front panel USB State
F-20
0 = Absent, 1 = Mass Storage
Rear panel USB State
F-21
0 = Absent, 2 = USB-CDC,
3 = GPIB-USB adapter
Rear panel USB mode
F-22
0 = Disable, 1 = GPIB-USB adapter,
2 = USB CDC
GPIB address
F-23
0~30
LAN settings
MAC Address-1
F-30
0x00~0xFF
MAC Address-2
F-31
0x00~0xFF
MAC Address-3
F-32
0x00~0xFF
MAC Address-4
F-33
0x00~0xFF
MAC Address-5
F-34
0x00~0xFF
MAC Address-6
F-35
0x00~0xFF
LAN
F-36
0 = Disable, 1 = Enable
DHCP
F-37
0 = Disable, 1 = Enable
IP Address-1
F-39
0~255
IP Address-2
F-40
0~255
IP Address-3
F-41
0~255
IP Address-4
F-42
0~255