User Manual

REMOTE CONTROL
57
Syntax
[SOURce:]CURRent:SLEW:FALLing {<NRf>|MIN|MAX}
Query Syntax
[SOURce:]CURRent:SLEW:FALLing? [MIN|MAX]
Parameter/Return
NRf
0.01A/s~200% (PSW 30-36)
0.1A/s~200% (PSW 30-72)
0.1A/s~200% (PSW 30-108)
0.01A/s~200% (PSW 80-13.5)
0.01A/s~200% (PSW 80-27)
0.01A/s~200% (PSW 80-40.5)
MIN
Minimum falling current slew rate
MAX
Maximum falling current slew rate
Example
SOUR:CURR:SLEW:FALL 1
Sets the falling current slew rate to 1A/s.
[SOURce:]RESistance[:LEVel][:IMMediate]
[:AMPLitude]
Set
Query
Description
Sets or queries the internal resistance in ohms.
Syntax
[SOURce:]RESistance[:LEVel][:IMMediate][:AMPLitude]
{<NRf>|MIN|DEF|MAX|?}
Query Syntax
[SOURce:]RESistance[:LEVel][:IMMediate][:AMPLitude]
? [MIN|MAX]
Parameter/Return
<NRf>
Resistance in ohms:
0.000Ω~0.833Ω (PSW 30-36)
0.000Ω~0.417Ω (PSW 30-72)
0.000Ω~0.278Ω (PSW 30-108)
0.000Ω~5.926Ω (PSW 80-13.5)
0.000Ω~2.963Ω (PSW 80-27)
0.000Ω~1.975Ω (PSW 80-40.5)
MIN
Minimum internal resistance in ohms
MAX
Maximum internal resistance in ohms
Example
SOUR:RES:LEV:IMM:AMPL 0.1
Sets the internal resistance to 100m.
[SOURce:]VOLTage[:LEVel][:IMMediate]
[:AMPLitude]
Set
Query
Description
Sets or queries the voltage level in volts.