User manual

REMOTE CONTROL
77
TRIGger:OUTPut[:IMMediate]
Set
Description
Generates a software trigger for the output trigger
system. On a trigger, sets the output state. Refer to
the :OUTP:TRIG command on page 62.
Syntax
TRIGger:OUTPut[:IMMediate]
Related
commands
OUTPut[:STATe]:TRIGgered
TRIGger:OUTPut:SOURce
Set
Query
Description
Sets or queries the trigger source for the output
system.
Syntax
TRIGger:OUTPut:SOURce [BUS | IMMediate]
Query Syntax
TRIGger:OUTPut:SOURce?
Parameter/Return
BUS
Internal software trigger. Waits for the
*TRG (or IEEE 488.1 “get” group
execute trigger) command to start the
trigger.
IMMediate
Starts the trigger immediately.
(default)
Example
TRIG:OUTP:SOUR BUS
Sets the trigger source of the output system as BUS.
Trigger Command Examples
1. The transient system for the trigger in immediate mode.
Example 1
TRIG:TRAN:SOUR IMM
CURR:TRIG MAX
VOLT:TRIG 5
INIT:NAME TRAN
<==The current changes to the
maximum, and the voltage
changes to 5V.