User manual

REMOTE CONTROL
85
Example
SYST:COMM:ENAB 1,USB
Turns the USB interface on.
Query Example
SYST:COMM:ENAB? USB
1
Queries the USB state, returns 1 (USB is on).
SYSTem:COMMunicate:GPIB[:SELF]:ADDR
ess
Set
Query
Description
Sets or queries the GPIB address. This setting is
applied only after the unit is reset.
Syntax
Query Syntax
SYSTem:COMMunicate:GPIB[:SELF]:ADDRess <NR1>
SYSTem:COMMunicate:GPIB[:SELF]:ADDRess?
Parameter/Return
<NR1>
0~30
Example
SYST:COMM:GPIB:SELF:ADDR 15
Sets the GPIB address to 15.
SYSTem:COMMunicate:LAN:IPADdress
Set
Query
Description
Sets or queries LAN IP address. This setting is
applied only after the unit is reset.
Syntax
Query Syntax
SYSTem:COMMunicate:LAN:IPADdress <string>
SYSTem:COMMunicate:LAN:IPADdress?
Parameter/Return
<string>
LAN IP address in string format ( “address”)
Applicable ASCII characters: 20H to 7EH
Example
SYST:COMM:LAN:IPAD “172.16.5.111
Sets the IP address to 172.16.5.111.
SYSTem:COMMunicate:LAN:GATEway
Set
Query
Description
Sets or queries the Gateway address. This setting is
applied only after the unit is reset.