User manual
PSW Series Programming Manual
88
1
Web password on
ON
Web password on
Return parameter
0
<boolean> Web password off
1
<boolean> Web password on
SYSTem:COMMunicate:LAN:WEB:PASSword
Set
Query
Description
Sets or queries the web password. This setting is
applied only after the unit is reset.
Syntax
Query Syntax
SYSTem:COMMunicate:LAN:WEB:PASSword <NR1>
SYSTem:COMMunicate:LAN:WEB:PASSword?
Parameter/Return
<NR1>
0 ~ 9999
Example
SYST:COMM:LAN:WEB:PASS 1234
Set the web password as 1234.
SYSTem:COMMunicate:RLSTate
Set
Query
Description
Sets or queries the control state of the instrument.
Note
Only applicable for software version 1.60 or above.
Syntax
Query Syntax
SYSTem:COMMunicate:RLSTate {LOCal | REMote |
RWLock}
SYSTem:COMMunicate:RLSTate ?
Parameter
LOCal
Sets the instrument to front panel control.
REMote
Sets the instrument to remote interface
control.
RWLock
Disables the front panel keys and only allows
the instrument to be controlled via the remote
interface.
Return parameter
LOC
The instrument is set to front panel control.
REM
The instrument is set to remote interface
control.
RWL
The front panel keys are disabled. The
instrument can only be controlled via the
remote interface.
Example
SYST:COMM:RLST: LOC
Sets the instrument to front panel control.