Instructions
PSW Series User Manual
116
APPENDIX
PSW Default Settings
The following default settings are the factory configuration settings
for the power supply (Function settings/Test settings).
Normal Function
Settings Setting Default Setting
Output ON delay time F-01 0.00s
Output OFF delay time F-02 0.00s
V-I mode slew rate select
F-03 0 = CV high speed priority
Rising voltage slew rate F-04 60.00V/s (PSW 30-XX)
160.0V/s (PSW 80-XX)
Falling voltage slew rate F-05 60.00V/s (PSW 30-XX)
160.0V/s (PSW 80-XX)
Rising current slew rate F-06 72.00A/s (PSW 30-36)
144.0A/s (PSW 30-72)
216.0A/s (PSW 30-108)
27.00A/s (PSW 80-13.5)
54.00A/s (PSW 80-27)
81.00A/s (PSW 80-40.5)
Falling current slew rate F-07 72.00A/s (PSW 30-36)
144.0A/s (PSW 30-72)
216.0A/s (PSW 30-108)
27.00A/s (PSW 80-13.5)
54.00A/s (PSW 80-27)
81.00A/s (PSW 80-40.5)
Internal resistance
setting
F-08
0.000
Ω
Bleeder circuit control F-09 1 = ON
Buzzer ON/OFF control F-10 0 = ON
USB/GPIB setting
Front panel USB State F-20 0 = Absent