Master-Slave Series Overview
Background
When connecting PSW power supplies in
series, up to 2 units can be used in series and all
units must be of the same model.
When the units are used in series, a number of
precautions and limitations apply. Please read
this overview before operating the power
supplies in series.
Limitations
Display
Only the master unit will display the
current.
Master and slave units display the voltage.
The total voltage is the sum of the units.
OVP/OCP
The master unit can shut down the slave
unit when OVP/OCP is tripped on the
master unit (if the slave connector is wired
for shut down on alarm).
OVP and OCP level is determined by the
master OVP and OCP level. The OVP and
OCP level on the slave unit is ignored.
Remote monitoring
Voltage monitoring (VMON) and current
monitoring (IMON) are only supported on
the master unit.
Remote Sense
Please see the remote sense chapter for
details, page 50.