Instructions

PSW Series User Manual
62
Voltage controlled remote control
Voltage controlled remote control can only
be used with the master unit.
Output Voltage/
Output Current
Model Single unit 2 units
PSW 30-36 30V 60V
36A 36A
PSW 80-13.5 80V 160V
13.5 13.5A
PSW 30-72 30V 60V
72A 72A
PSW 80-27 80V 160V
27A 27A
PSW 30-108 30V 60V
108A 108A
PSW 80-40.5 80V 160V
40.5A 40.5A
Master-Slave Series Connection
Master-Slave
Connector
The Analog Control Connector is used for both
serial and parallel connections. The way the
connector is configured determines the
behavior of the master and slave units. For the
connector pin assignment, see page 89.
Analog Connector
Connection
To operate the power supplies in series, connect
the analog connectors on the master and slave
unit as shown in the diagram below.