Instructions

CONFIGURATION
77
Gateway-3 F-49 0~255
Gateway-4 F-50 0~255
DNS address -1 F-51 0~255
DNS address -2 F-52 0~255
DNS address-3 F-53 0~255
DNS address-4 F-54 0~255
Sockets active F-57 0 = Disable, 1 = Enable
Web Server active F-59 0 = Disable, 1 = Enable
Web password active F-60 0 = Disable, 1 = Enable
Web setting password F-61 0000~9999
Power On Configuration Settings*
CV Control
F-90
0 = Panel control (local)
1 = External voltage control
2 = External resistance control
(Ext-R
10k = Vo, max)
3 = External resistance control
(Ext-R
10k = 0)
CC Control F-91
0 = Panel control (local)
1 = External voltage control
2 = External resistance control
(Ext-R
10k = Io,max)
3 = External resistance control
(Ext-R
10k = 0)
Power-ON Output F-92 0 = OFF at startup, 1 = On at startup
Master/Slave F-93
0 = Master/Local
1 = Master/Parallel1
2 = Master/Parallel2
3 = Slave/Parallel
4 = Slave/Series
External Out Logic F-94 0 = High ON, 1 = Low ON
Power Switch trip F-95 0 = Enable , 1 = Disable
Calibration Settings*
Calibration F-00 0000 ~ 9999
*Note
Power On and Calibration settings can only be set
during power up.