User manual

ANALOG CONTROL
135
External Operation and Status Monitoring
Background
Name and Pin
Description
STATUS COM
17
Common (photo coupler
emitter) for status signals 18,
19, 20, 21 and 22.
CV STATUS
18
Low when CV mode is active.
CC STATUS
19
Low when CC mode is active.
ALM STATUS
20
Low when any of the protection
modes are tripped (OVP,
OCP). Active low.
OUT ON
STATUS
21
Low when the output is on.
PWR OFF
STATUS
22
Active low.
17
Pins 18, 19, 20, 21, 22