User Manual

OPERATION
69
Only operate the power supplies in parallel if
the units are configured correctly.
1. Turn on the master and slave units. The slave
unit(s) will show a blank display.
Master unit
Slave units
2. Operation of all units is controlled
via the master unit. Operation of
the master unit is the same as for a
single unit. See the Basic Operation
chapter.
Page 45.
3. Press the Output key to begin.
Output
Only operate the power supplies in parallel if using
units of the same model number.
Only a maximum of 3 units can be used in parallel.
The panel controls are disabled on slave units,
including the output key. On slave units only the
Function key can be used to view the current
settings.