User guide
SETUP
25
Output On/Off
Panel operation
Pressing the Output key
once Turns On the output, all
channels 1/2/3 at once.
O
U
T
P
U
T
ON / OFF
O
U
T
P
U
T
ON / OFF
Pressing again turns Off the
output.
OUTPUT
ON / OFF
OUTPUT
ON / OFF
Automatic Output
Off
Any of the following actions during output On
automatically turns it Off. They might involve
sudden and harmful change in the output level.
Change the range
60V/3A
30V/6A
Change the tracking SW
between independent /
series / parallel
T
R
A
C
KI
N
G
INDEP.
SERIES
PA
R
A
L
L
E
L
OVP tripped
O
.
V
.P.
SET
TRIP
O.V.P.
SET
TRIP
OVP SET mode
CH3CH2CH1
O.V.P. SETNORMAL
Remote control
When in remote control
mode (page39), front panel
output control is disabled.
CV/CC red
without output
Red CV/CC indicator when
output Off indicates internal
error. Contact the service
center.
C.V.
C.C.
+
O
U
T
P
U
T
ON / OFF
SPD-3606 User Manual
26
OPERATION
CH1/CH2 Independent Mode
Background /
Connection
Channel1 and Channel2 outputs work
independent
of each other and are separately controlled.
CH2
CH1
CH2
LOAD
CH1
LOAD
Output rating
0 ~ 30V/0~6A or 0~60V/0~3A for each channel
Setting step
1. Select the output range,
60V/3A or 30V/6A. Set the
CH1/CH3 meter switch to
the CH1 position.
60V/3A
30V/6A
CH1
CH3