User guide

SAFETY INSTRUCTION
5
SAFETY INSTRUCTION
This chapter contains important safety instructions
that you must follow when operating SPD-3606
and when keeping it in storage. Read the
following before any operation to insure your
safety and to keep the best condition for SPD-3606.
Safety Symbols
These safety symbols may appear in this manual or on SPD-3606.
WARNING
Warning: Identifies conditions or practices that
could result in injury or loss of life.
CAUTION
Caution: Identifies conditions or practices that
could result in damage to SPD-3606 or to other
properties.
DANGER High Voltage
Attention Refer to the Manual
Protective Conductor Terminal
Earth (ground) Terminal
SPD-3606 User Manual
6
Safety Guidelines
General Guideline
CAUTION
Do not place any heavy object on SPD-3606.
Avoid severe impacts or rough handling that
leads to damaging SPD-3606.
Do not discharge static electricity to SPD-3606.
Do not block or obstruct the cooling fan vent
opening.
Leave a space around SPD-3606, at least 3cm to
the left and right.
Do not perform measurement at circuits directl
y
connected to Mains (Note below).
Do not disassemble SPD-3606 unless you are
qualified as service personnel.
(Measurement categories) EN 61010-1:2001 specifies the
measurement categories and their requirements as follows. SPD-
3606 falls under category I.
Measurement category IV is for measurement performed at the
source of low-voltage installation.
Measurement category III is for measurement performed in the
building installation.
Measurement category II is for measurement performed on the
circuits directly connected to the low voltage installation.
Measurement category I is for measurements performed on
circuits not directly connected to Mains.
Power Supply
WARNING
AC Input voltage: 115V/230V ±15%, 50/60Hz
Connect the protective grounding conductor of
the AC power cord to an earth ground, to avoid
electrical shock.
Fuse
WARNING
Fuse type: T10A/250V
Make sure the correct type of fuse is installed
before power up.