Recommended combinations / Electrode grinding
Current (A) Ø Electrode (mm)
= Ø wire (filler metal)
Ø Nozzle (mm) Flow rate (Argon L/mn)
0,5-5 10-130 1,6 9,8 6-7
4-6,5 130-200 2,4 11 7-8
> 6.5 > 200A 3,2 12,7 8-9
To optimise the welding process, it is recommended to grind the electrode prior to welding as described in the
diagram below :
d
l
Trigger command connector
The trigger command socket is laid out in the following way:
DUTY CYCLE
The welding unit describes an output characteristic of a "constant current". The duty cycles following the norm
EN60974-1 (at 40°C on a 10mn cycle) are indicated in the table below :
Note : The machines’ duty cycle has been tested at room temperature (40°C) and has been determined by
simulation.
L = 3 x d for a low current
L = d for a high current
L
3
1
4
5
2
Gysmi TIG 168
Switch GND
Cold current button
Welding torch button
Gysmi TIG 200/ 250
Switch GND + Potentiometer
Cold current button
Welding torch button
Cursor / potentiometer
+5V potentiometer 10 KΩ
GYSMI TIG 168
X% @
I max X% @
I max
21% 160A 15% 160A
60% 100A 60% 80A
100%
90A 100% 70A
GYSMI TIG 200 (230V)
X% @
I max X% @
I max
30% 200A 20% 200A
60% 140A 60% 125A
100%
125A 100% 110A
GYSMI TIG 200 (110V)
X% @
I max X% @
I max
26% 180A 30% 120A
60% 115A 60% 90A
100%
100A 100% 80A
GYSMI TIG 250
X% @
I max X% @
I max
33% 250A 24% 250A
60% 170A 60% 160A
100%