Brochure
EASYCUT 25 EASYCUT K25 EASYCUT K35F EASYCUT 30 FV EASYCUT 40 CUTTER 45 CT CUTTER 70 CT NEOCUT 105 NEOCUT 125
Max. output current
25 A 25 A 35 A 30 A 40 A
Max. output current
45 A 70 A 105 A 125 A
Mains voltage 230 V - 1~ 230 V - 1~ 230 V - 1~ 110/230 V - 1~ 230 V - 1~ Mains voltage
110 V
1~
230 V
1~
400 V - 3~ 400 V - 3~ 400 V - 3~
Performance de
coupe (mm)
Separation
Steel
8 8 15 15 20
Performance de
coupe (mm)
Separation
Steel
15 30 35 40 57
Recommended 6 6 10 10 15 Recommended 10 25 25 35 40
Drilling - - - - - Drilling 5 12 15 20 25
Mechanised cutting - - - - - Mechanised cutting
Internal compressor
- - -
Internal compressor
- - - -
Automatic
air pressure control
- - - - -
Automatic
air pressure control
- -
Marking - - - - - Marking - -
Gouging - - - - - Gouging -
Protection rating IP 21 IP 21S IP 21 IP 21S IP 21 Protection rating IP 23 IP 23 IP 23 IP 23
Weight (kg) 7.8 15 30 11 8 Weight (kg) 15 22 33 36
Part no. with accessories* 065543 068063 031036 013858 029743 Part no. with accessories* 062962 013841 063112 067448
MANUAL CUTTING MANUAL OR MECHANISED CUTTING
GYS PLASMA cutter range
25 A - 125 A
Glossary
Discover the technological features of our products as
well as a brief explanation.
PFC
Power Factor Correction (PFC)
PFC technology suppresses spikes and regulates the supply current.
The electrical network is therefore better used, accepting supply voltages between 185 and
265 V and, therefore, favouring the use of extension cords or power supplies. Another im-
portant eect is that a power source equipped with this device consumes much less energy
from the grid and allows it to be used on smaller circuit breakers (e.g. 16 A).
FV
Flexible Voltage
This technology extends the supply voltage range of the PFC from 85 to 265 V (185 to 265 V
for a standard PFC). They can therefore be used on 110 V or 230 V electrical networks.
P400
Protect 400
Power sources equipped with this technology are able to withstand occasional or perma-
nent voltage variations on the electrical network up to 400 V (lightning, engine-driven sets,
load shedding, etc.).
AD
Anti-Dust
In this type of design, the ventilation corridor is isolated from the electronic parts, which
greatly reduces contact with external dust.
Mechanised cutting
Can be connected to a CNC cutting table.
MMA
Internal air compressor
Eliminates the need for a nearby compressed air source.
MMA
AIR
auto
Auto AIR
Automatic management of air pressure and ow for optimal cutting.
Open sheet mode
Ideal for cutting work on perforated sheets
MMA
Marking mode
Ideal for surface marking and part identication.
Gougeage
G
Gouging
Removal of metal in an ecient, precise and clean manner
*Power source + earth clamp
+ hand-held torch
*Power source + earth clamp
+ hand-held torch MT-70 or MT-125
5
www.gys.fr
4