- Disconnect the cooling liquid pipes and unlock the lever.
- Remove the clamp arm.
- Lubricate both a new arm and the support with contact grease (ref.050440).
Specic Installation for C2 and C8 arms
For these arms, the Stretches will also need to be changed. Unscrew the short stretches with a at
spanner and remove the injector. Centre the injector along the axle of the clamp (Caution: beveled side outside) and insert it manually(1)
Position the long stretches in front and screw it on to the clamp axle (maximum torque 15Nm) (2).
Long Stretches
Long Injector
Short Injector
Short Stretches
Stretches types:
Short: C1, C3, C4, C5, C6, C7, C9, C10, C12, C14
Long: C2, C8
ADJUSTMENT OF C ARMS
1
2
3
4
- Lower the locking knob
1
which allows over-opening.
- Pull out the adjustment knob
2
and turn it so that it rests
on the pin
3
.
- Tighten the toothed ring
4
by hand and then turn the
adjustment knob
2
so that returns to its seat and pre-