Manual

BATIUM 7/12 • 7/24 • 15/12 • 15/24
9
EN
Translation of the original instructions
Regulations:
• The device complies with European Directive.
The certicate of compliance is available on our website.
EAC conformity mark (Eurasian Economic Commission).
Equipment in compliance with British requirements. The Brit-
ish Declaration of Conformity is available on our website (see
home page).
• Equipment in conformity with Moroccan standards.
The declaration Cم (CMIM) of conformity is available on our
website (see cover page).
Disposal:
This product should be disposed of at an appropriate recycling
facility. Do not dispose of in domestic waste.
GENERAL DESCRIPTION
The Batium range is designed to charge all common batteries including lead-acid , electrolyte or gel batteries.
Reference 7 / 12 7 / 24 15 / 12 15 / 24
Voltage 6 V 12 V 6 V 12 V 24 V 6 V 12 V 6 V 12 V 24 V
Battery capacity From 15 Ah to 130 Ah From 35 Ah to 225 Ah
CONNECTIONS AND GENERAL OPERATIONS
Ensure that the correct sequences are followed.
Precaution: Check the electrolyte level for open batteries. Fill it up if necessary, before starting the charge.
1. Connect the clamps : Red clamp to the battery's (+) and black clamp to the battery's (-).
2. Connect the charger to the mains on a 230 V socket. An indicator
A
(interface diagram p.44) and
B
switches on that matches the latest saved data.
3. Select the battery voltage (6, 12, 24 V) according to the recommendations
features on the battery or according to the battery coupling (series or parallel cf
p.44).
Risk of explosion or acid projections if the wrong voltage
is selected (24V for a 12V battery).
To conrm the selec-
tion, do not press any
button for 5 seconds.
4. Select the battery capacity. The Batium automatically determines the char-
ging current.
5. The charge starts automatically. The display indicates the battery's state of charge. (indicators
1
and
2
)
Voyant allumé État
Step 1 :
Voltage rises
Permanent
Step 2 :
Voltage regulation (duration : 2h).
Flashing
Step 3 :
Charge ends (Floating charge).
Green
In the event of a power cut, the BATIUM saves the state of charge (except in « SOS Recovery » mode),
and resumes the charge using the latest settings.
6. When the battery is charged, disconnect the power supply
7. Disconnect the clamps or the battery connectors.