Manual

BATIUM 7/12 • 7/24 • 15/12 • 15/24
10
EN
Translation of the original instructions
FORCED CHARGE
If the battery is deeply discharged (very low voltage <2 V), the charge doesnt not start automatically. The charge
indicator
1
does not switch on. The battery voltage indicators
A
, and capacity indicator
B
are switched on. In this
situation, select the voltage and the charging current, then press the battery voltage button
3
during 5 seconds to start
a "forced charge". The indicator
1
switches on once the buttton is released. If no indicator switches on, your battery
cannot be recovered (<0.5 V (± 0.3)).
« SOS RECOVERY » (BATIUM 15/12 AND 15/24)
When connecting the battery, the SOS Recovery indicator
6
ashes to signal that the battery suffered a deep di-
scharge over a long period, with a start in sulfation.
The « SOS Recovery » mode uses a specic curve to repair the battery over a 24 to 48 hours cycle.
To activate this feature, follow these steps :
1. Disconnect the battery from the vehicle. (OVERVOLTAGE DANGER)
2. Connect the Batium to the battery.
3. Connect the Batium to the mains.
4. Choose the charging voltage.
5. Activate « Sos Recovery » by pressing the button
4
during 5 seconds, until the indicator
6
switches on (the indicators
B
are switched off).
6. The indicator
1
switches on and blinks when the "Sos Recovery" stops and the normal charge resumes.
7. The green indicator
2
indicated the charge is over.
PROTECTIONS
The Batiums are protected against short-circuits, polarity reversals and vehicle start (they maintain a constant charge
even when the vehicle is started). It has an anti-spark feature which prevents sparks whilst connecting the Gysash to
the battery. The Batium will not deliver current if there is no battery detected (no voltage in the clamps).
TROUBLESHOOTING
ANOMALIES CAUSES SOLUTIONS
1
The charge indicator 1 is swit-
ched off. The battery voltage
indicators blink alternatively
after 1 minute of charging.
The selected voltage does not
match the battery voltage.
- Unplug the device from the mains while
holding the clamps on the battery.
- Reconnect the BATIUM to the mains
supply.
- Select the correct voltage within 5
seconds of reconnecting the product.
The battery cannot be recovered. Change the battery.
2
The battery capacity indica-
tors ash alternatively.
The battery is in short circuit or
damaged
Change the battery.
A power consumer has been left
on accidentally (e.g. lights).
Switch off the power consumer and
continue/restart the charge
The charger is used as a power
supply to compensate for the use
of power consumers that are drag-
ging the battery's energy.
Charger behaves normally but incorrect
use. The indicator that signals the end
of the charge cannot switch on.
The battery capacity (Ah) is higher
than the charger's
The charging time will be abnormally
long. If possible, use a more powerful
charger
Choose the capacity indicated on your
battery.
The battery voltage does not rise,
the battery is damaged.
Change the battery.