Manual

14
DIAG-STARTIUM 60-12 / 60-24
EN
Translation of the original instructions
Regularly take off the cover and remove dust with an air gun. Take
the opportunity to have a qualied person check the electrical
connections with an insulated tool.
Under no circumstances should solvents or other aggressive
cleaning agents be used.
• Clean the devices surfaces with a soft, dry cloth.
Regulations
• The device complies with European Directive.
The certicate of compliance is available on our website.
EAC conformity mark (Eurasian Economic Commission)
Equipment in compliance with British requirements. The British
Declaration of Conformity is available on our website (see home
page).
• Equipment in conformity with Moroccan standards.
The declaration Cم (CMIM) of conformity is available on our
website (see cover page).
Disposal:
This product should be disposed of at an appropriate recycling
facility. Do not dispose of in domestic waste.
GENERAL DESCRIPTION
DIAG-STARTIUM products are designed for charging and starting 12V (6 elements) lead acid batteries (electrolyte, Gel
and AGM) for the model 60-12 and 6V (3 elements), 12V (6 elements) and 24V (12 elements) for the model 60-24:
Assembly - handle and wheels :
POWER SUPPLY
Check that the power and protection (fuse and / or circuit breaker) are compatible with the current required. The
appliance must be positioned so that the plug socket is accessible.
It must be connected to a grounded outlet according to the following recommendation:
DIAG-STARTIUM 60-12 DIAG-STARTIUM 60-24
Power supply 230V - 1 ph 230V - 1 ph
Protection
16 A 16 A
Charging
power
charge
2000 W 2000 W
Starting
10 000 W 10 000 W
The recommended cross-section for an extension is : 3 x 2,5 mm².