Manual
14
DIAG-STARTIUM 60-12 / 60-24
EN
Translation of the original instructions
• Regularly take off the cover and remove dust with an air gun. Take
the opportunity to have a qualied person check the electrical
connections with an insulated tool.
• Under no circumstances should solvents or other aggressive
cleaning agents be used.
• Clean the device’s surfaces with a soft, dry cloth.
Regulations
• The device complies with European Directive.
• The certicate of compliance is available on our website.
• EAC conformity mark (Eurasian Economic Commission)
• Equipment in compliance with British requirements. The British
Declaration of Conformity is available on our website (see home
page).
• Equipment in conformity with Moroccan standards.
• The declaration Cم (CMIM) of conformity is available on our
website (see cover page).
Disposal:
• This product should be disposed of at an appropriate recycling
facility. Do not dispose of in domestic waste.
GENERAL DESCRIPTION
DIAG-STARTIUM products are designed for charging and starting 12V (6 elements) lead acid batteries (electrolyte, Gel
and AGM) for the model 60-12 and 6V (3 elements), 12V (6 elements) and 24V (12 elements) for the model 60-24:
Assembly - handle and wheels :
POWER SUPPLY
Check that the power and protection (fuse and / or circuit breaker) are compatible with the current required. The
appliance must be positioned so that the plug socket is accessible.
It must be connected to a grounded outlet according to the following recommendation:
DIAG-STARTIUM 60-12 DIAG-STARTIUM 60-24
Power supply 230V - 1 ph 230V - 1 ph
Protection
16 A 16 A
Charging
power
charge
2000 W 2000 W
Starting
10 000 W 10 000 W
The recommended cross-section for an extension is : 3 x 2,5 mm².