CONNECTION AND DISCONNECTION
Before any connection to a vehicle battery, make sure
that the booster isn’t connected to the mains and that the
booster’s switch is set to OFF.
Locate the + and - battery terminals. (polarity reversal can
damage the fuse).
Keep the cables away from hot or sharp surfaces. Separate
the 2 cables properly and avoid pinching them.
Once the connector is plugged on «12V» or «24V», a LED switches on under the corresponding interface to conrm the
selected voltage input. If the selected voltage does not match the battery voltage, the charge cannot start.
Diag-Startium 60-12 Diag-Startium 60-24
Start and charge a battery in-situ :
In the event that the negative terminal is plugged onto the car’s chassis :
1. Connect the red clamp to the battery’s positive terminal.
2. Connect the black clamp to the vehicle’s chassis, make sure it is a safe distance from the battery and the
fuel/exhaust pipe.
3. Connect the device to the mains.
4. Choose the user mode, charge speed and switch the DIAG-STARTIUM on.
5. After use, set the switch to OFF, disconnect the charger from the mains then remove the black clamp,
followed by the red clamp.
Some vehicles have the positive terminal plugged onto the car chassis, in this event :
1. Connect the black clamp to the battery’s negative terminal.
2. Connect the red clamp to the vehicle’s chassis, make sure it is a safe distance from the battery and the
fuel/exhaust pipe.
3. Connect the device to the mains.
4. Choose the user mode, charge speed and switch the DIAG-STARTIUM on.
5. After use, set the switch to OFF, disconnect the charger from the mains then remove the red clamp rst
and the black clamp last.
Charging a battery when disconnected from the vehicle :
1.
Connect the red clamp to the battery’s positive terminal and the black clamp to the battery’s negative
terminal.
2. Connect the device to the mains.
3. Choose the user mode, charge speed and switch the DIAG-STARTIUM on.
4. After use, set the switch to OFF, disconnect the charger from the mains then remove the red clamp rst