Instructions

17
GYSFLASH 100.12 HF / 102.12 HF
EN
POWER SUPPLY MODE CONFIGURATION
POWER SUPPLY
U=19.6V I<30A
POWER SUPPLY
U=19.6V I<10A
2.0V
2.1V
...
16.0V
2A
3A
...
100A
POWER SUPPLY
U=13.5V I<30A
Start up :
• Push the START/STOP key to start the mode.
• During use, the current consumed and the instan-
taneous voltage are displayed.
POWER SUPPLY START UP
POWER SUPPLY
U=19.6V I<50A
POWER SUPPLY
U=19.6V I=10A
NOTE: Unlike other modes, Power Supply mode, the charger does not compensate cables voltage drop. In this case, the voltage
displayed on the screen corresponds to the output voltage of the charger (not the voltage on the clamps).
CONFIGURATION MENU
Access to conguration menu :
MODE
3 sec - Mode
To browse in the sub menu press the
«Select» key :
SELECT
languages > restart > lock showroom > cable check > ADVANCED
MENU > Reset Memory
Sub menu :
• Languages :
This menu enables to select the language (use the arrows to change the
language).
• Automatic restart :
Automatic restart only works with «Showroom», «Charge» and «Power
Supply» mode. This feature enables charger to restart automatically and
to restart charging after a cut in power. To activate the «Automatic res-
tart» feature « Conguration | Restart : ON ».
• Lock Showroom :
To lock the device in Showroom Mode (to avoid misuse). To activate the
«Lock Showroom» feature « Conguration | Lock Showroom : Y ».
CONFIGURATION MODE
SETTINGS
English
SETTINGS
restart: OFF
Y (yes)
N (no)
ON
OFF
English
Francais
Deutsch
Nederlands
Espanol
Portugues
Italiano
Russian
...
SETTINGS
Cables Testing:
Press START
SETTINGS
lock showroom: N
SETTINGS
Advanced Menu:
Press START
SETTINGS
Reset Memory:
Press START
Cables testing
Advanced menu
Reset Memory