Instructions

19
GYSFLASH 100.12 HF / 102.12 HF
EN
ADVANCED MENU
This menu controls the advanced parameters of the charger. To move from one parameter to another push the Select key :
SELECT
Activation «Change battery» > Activation «Power Supply» > Activation «Expert Curve» (> Adjusment of the
«Expert Curve» parameters)
• CHANGE BATTERY mode activation:
To activate the CHANGE BATTERY mode, select «ADVANCED MENU |
Change bat: ON». Now this mode will be accessible from the mode list.
• POWER SUPPLY mode activation:
To activate the POWER SUPPLY mode, select «ADVANCED MENU | Power
Supply: ON». Now this mode will be accessible from the mode list.
• «EXPERT» curve activation:
To activate the «RECOV» curve, select «ADVANCED MENU | Expert curve:
ON». Now this curve will be available in the charging curves list from the
CHARGE mode.
• Parameters adjustment of the «Expert» curve:
If the charging curve is activated, the charging curve parameters can be
adjusted (type IU
0
I
0
U):
- Ucharge: Charge voltage adjustable from 12.0 to 16.0V (Step 7).
- Icharge: Charging current adjustable from 10A to 200A per 100Ah of
specied capacity (Step 6).
- Urecovery: Recovery voltage adjustable up to 30.0V.
If the value «OFF» is selected the recovery function is inactive (Step 2
and 4).
- Uoating: Floating voltage adjustment.
If the value «OFF» is selected the oating function is inactive (Step 9).
- Trecovery: Maximum time for shorted cells recovery, adjustable from
1h to 24h (Step 2).
- Trefresh: Time for the refreshing phase adjustable from 1h to 12h. If
the value «OFF» is selected, the refresh function is not activated (Step 8).
- T desulfat: Maximum time adjustable from 1h to 24h of the desulfation
phase (Step 4).
- T ch_max: Maximum charging time (Step 7 and 6).
- T ch_min: Minimum charging time (Step 7 and 6).
- Urefresh: Maximum voltage during the cooling phase (Step 8).
- OCP (Over Charge Protection): Maximum percentage of the nominal
capacity which can be injected before the protection begins.
aWarning:
When charging in-situ, a «Urecovery» or «Urefresh» too high
might damage the electronics of the vehicle. We advise NOT to
adjust these settings above 15V.
To save and validate the new settings, select «ADVANCED MENU» | save? Yes»
Push the «MODE» key to exit the «Conguration» menu.
ADVANCED MENU
ON
OFF
ADVANCED MENU
Power Supply: OFF
EXPERT CURVE
Uoating: OFF
EXPERT CURVE
Ucharge: 14.3V
EXPERT CURVE
Urecovery: OFF
ON
OFF
ON
OFF
ADVANCED MENU
expert curve: OFF
EXPERT CURVE
T recovery: 5h
1h
2h
...
24h
EXPERT CURVE
T desulfat: 12h
1h
2h
...
24h
EXPERT CURVE
Tch_max: 16h
1h
2h
...
36h
EXPERT CURVE
Tch_min: 0h
0h
1h
...
Tch_max
EXPERT CURVE
T refresh: 5h
OFF
1h
2h
...
12h
EXPERT CURVE
U refresh: 16.0V
Uch
...
15.9V
16.0V
EXPERT CURVE
OCP: 200%
100%
...
245%
250%
ADVANCED MENU
Save? No
Yes
No
RETURN
OFF
Uch
...
15.9V
16.0V
10A/100Ah
11A/100Ah
...
200A/100Ah
OFF
12.0V
12.1V
...
Uch
ON
OFF
ADVANCED MENU
Change bat.: OFF
EXPERT CURVE
Ichrg: 20A/100Ah
12.0V
12.1V
...
16.0V