Manual
EN
5
Operating manual
Replacement of ferrites
Translation of the original
instructions
Do not mount the inductor at more than 100°C at the risk of damaging the joints.
6. Finish with Scotch-Brite or sandpaper.
7. For optimum bonding results, the copper piping must be clean and free of all traces of glue.
Before reassembling the ferrite, it must be tted in the PTFE cover.
8. Apply glue using the glue kit (075948).
extra tube of glue (054851)
9. Position the ferrite assembly on the previously prepared/cleaned inductor.
10. Retighten the retaining spring plate screw if present (B1 & B4) or ret the protective cover on the ferrite (B2 & B3).
11. Wipe o excess glue.
12. Position the inductor so the ferrite is horizontal.
Wait at least 4 hours before handling. The setting/drying of the glue can be accelerated by heating (max 60°C).