List of synergic modes (V1012)
Std Ø0.6 Ø0.8 Ø1 Ø1.2 Puls Ø0.6 Ø0.8 Ø1 Ø1.2
Fe Arg CO2 18% X X X X X
Al Mg 5 Arg 100% X X X X X X
Al Si 12 Arg 100% X X X X
Al Si 5 Arg 100% X X X X X
Cr Ni 308 Arg 100% X X X X
Cr Ni 316 Arg 100% X X X X
Cu Si 3 Arg 100% X X X X
Cu Al 8 Arg 100% X X X X
Fe CO2 100% X X
Information panel
It contains the indices and sub-indices of the circuits and
the software version (HMI, power, SD card ...)
Example:
WELDING STAGES
Standard 2 times mode
OFF
Istart
Dstart
Gas Pre-Flow
T burn-back
I burn-back
ON
Gas post-Flow
Pressing the trigger will start pre-gas. When the wire touches the workpiece a pulse boots the arc and the the
welding process starts. When you stop pressing the trigger, the wire feeder stops working and a current pulse will
cut the wire, and will be followed by post-gas. As long as the post gas is not nished, you can pull the trigger to
carry on the welding (delay in manual). To modify the parameters you have to wait until the end of the post gas.