Operation Manual
25
NEOPULSE 270-T1 / 270-T2 / 300
EN
List of synergic modes (V1012)
Std Ø0.6 Ø0.8 Ø1 Ø1.2 Puls Ø0.6 Ø0.8 Ø1 Ø1.2
Fe Arg CO2 18% X X X X X
Al Mg 5 Arg 100% X X X X X X
Al Si 12 Arg 100% X X X X
Al Si 5 Arg 100% X X X X X
Cr Ni 308 Arg 100% X X X X
Cr Ni 316 Arg 100% X X X X
Cu Si 3 Arg 100% X X X X
Cu Al 8 Arg 100% X X X X
Fe CO2 100% X X
Information panel
It contains the indices and sub-indices of the circuits and
the software version (HMI, power, SD card ...)
Example:
WELDING STAGES
Standard 2 times mode
OFF
Istart
Dstart
Gas Pre-Flow
T burn-back
I burn-back
ON
Gas post-Flow
Pressing the trigger will start pre-gas. When the wire touches the workpiece a pulse boots the arc and the the
welding process starts. When you stop pressing the trigger, the wire feeder stops working and a current pulse will
cut the wire, and will be followed by post-gas. As long as the post gas is not nished, you can pull the trigger to
carry on the welding (delay in manual). To modify the parameters you have to wait until the end of the post gas.