Operation Manual
10
200E FV CEL
EN
FIRE AND EXPLOSIONS RISKS
Protect the entire welding area. Compressed gas containers and other inammable material must be
moved to a minimum safe distance of 11 meters.
A re extinguisher must be readily available at all times.
Be careful of spatter and sparks, even through cracks.
They can be the source of a re or an explosion.
Keep people, ammable objects and containers under pressure at a safe distance.
Welding of sealed containers or closed pipes should not be undertaken, and if opened, the operator must remove any
inammable or explosive materials (oil, petrol, gas...).
Grinding operations should not be directed towards the device itself or any ammable materials.
GAS BOTTLE
Gas leaking from the cylinder can create a hazard if present in high concentrations around the work
area.
Transport must be done safely: Cylinders closed and product off. Always keep cylinders in an upright
position securely chained to a xed support or trolley.
Gas cylinders must be stored in an open or ventilated area. The cylinders must be in a vertical position secured to
a support or trolley. Close the bottle after any welding operation. Be careful with gas bottles placed in areas of high
temperature, or in sunlight. Cylinders should be located away from areas where they may be struck or subjected to
physical damage. Always keep gas bottles at a safe distance from arc welding or cutting operations, and any source of
heat, sparks or ame.
Be careful when opening the valve on the gas bottle, it is necessary to remove the tip of the valve and make sure the
gas meets your welding requirements.
ELECTRIC SAFETY
The machine must be connected to an earthed electrical supply. Use the recommended fuse size.
An electrical discharge can directly or indirectly cause serious accidents, or death .
Never touch live parts inside or outside of the device when it is powered on (Torches, clamps, cables, electrodes) as they
are connected to the welding circuit.
Before opening the device, it is imperative to disconnect it from the electrical supply and wait 2 minutes so that all the
capacitors are discharged.
Do not touch the torch or electrode holder and earth clamp at the same time.
Be sure to change the cables and torches if they are damaged, to be performed by qualied and authorized personnel.
Ces accessoires doivent correspondre à la machine (taille, puissance...)
Always wear dry clothes in good condition, in order to be insulated from the electrical circuit. Wear insulating shoes,
regardless of the environment in which you work in.
EMC CLASSIFICATION
These Class A devices are not intended to be used on a residential site where the electric current is
supplied by the public network, with a low voltage power supply. There may be potential difculties in
ensuring electromagnetic compatibility on these sites, because of the interferences, as well as radio
frequencies.
This equipment complies with IEC 61000-3-12.
ELECTROMAGNETIC INTERFERENCES
The electric currents owing through a conductor cause electrical and magnetic elds (EMF). All wel-
ders should use the following guidelines to minimize exposure to the welding circuit’s electromagnetic
elds:
The EMF elds may disrupt some medical implants, such as pacemakers. Protection measures should
be taken for people wearing medical implants. For example, access restrictions for passers-by or an
individual risk evaluation for the welders.
All welders should take the following precautions in order to minimise exposure to the electromagnetic elds (EMF)
generated by the welding circuit::