Operation Manual

11/43
Recommended combinations / Electrode grinding
Current (A) Ø Electrode (mm)
= Ø wire (filler metal)
Ø Nozzle (mm) Flow rate (Argon L/mn)
0,5-5 10-130 1,6 9,8 6-7
4-7
130-190
2,4
11
7-8
To optimize the working, you have to use an electrode grinded as below :
d
l
REMOTE CONTROL
The remote control operates in TIG and MMA mode.
Connector technology
The CEL 250A TRI is equipped with a female socket for remote control. The specific 7 point male plug (product
ref.045699) enables connection to a manual remote control (RC) or foot pedal (PEd).
For the cabling layout, see the diagram below.
Connecting
1- Power up the machine
2- Plug the pedal/remote control to the connecting socket on the machine.
3- The screen will flash and display « No » (Nothing),
4- Select the type of control using keys :
« No » (Nothing) / « RC » (Remote Control) / « PEd » (Pedal)
5- After 2 seconds the display will freeze on the chosen selection, then displays the welding current.
NB: In case of error, unplug the remote control, (« No » will be displayed) and re-start the connection process.
Remark: Remote type choice will be required each time the machine is powered up.
Functions
Manual remote control (ref.045675) / Pedal (ref.045682):
The remote control enables the variation of current from minimum intensity (DC: 10A / MMA: 10A) to an intensity
defined by the user.
In this configuration, all modes and functions of the machine are accessible and can be set.
THERMAL PROTECTION & DUTY CYCLE
Thermal protection: thermal protection indicator turns on and the cooling time is about 2 to 5 min according to
external temperature.
Leave the machine connected to the supply after welding in order to let it cool down
The welding unit describes an output characteristic of "constant current" type. The duty cycles following the norm
EN60974-1 (at 40°C on a 10mn cycle) are indicated in the table here below :
CEL 250A TRI
X% @
I
max
X% @
I max
25%
250A
35%
250A
60%
180A
60%
200A
100%
160A
100%
180A
L = 3 x d for a low current
L = d for a strong current
L
D: Switch contact
C: Earth
B: Cursor
A: + 5V
Nb: The Potentiometer value must be 10 K
Ref.045699