Operation Manual

11
1- Press button for 3 seconds
2. Set the automatic arc slope from 1 to 10 sec (display) using key.
3. Validate the required figue by pressing button .
Recommended combinations / Electrode grinding
Current (A)
Ø Electrode (mm)
= Ø wire (filler metal)
Ø Nozzle
(mm)
Flow rate
(Argon L/mn)
0,5-5 10-130 1.6 9.8 6-7
4-8
130-200
2.4
11
7-8
To optimise the weld, use an electrode ground as below :
d
l
REMOTE CONTROL
The remote control operates in TIG and MMA mode.
Connector technology
The FLEX 250A CEL is equipped with a female socket for remote control. The specific 7 point male plug (product
ref.045699) enables connection to a manual remote control (RC) or foot pedal (PEd).
For the cabling layout, see the diagram below.
Connecting
1- Power up the machine
2- Plug the pedal/remote control to the connecting socket on the machine.
3- The screen will flash and display « No » (Nothing),
4- Select the type of control using keys :
« No » (Nothing) / « RC » (Remote Control) / « PEd » (Pedal)
5- After 2 seconds the display will freeze on the chosen selection, then displays the welding current.
NB: In case of error, unplug the remote control, (« No » will be displayed) and re-start the connection process.
Remark: Remote type choice will be required each time the machine is powered up.
Functions
Manual remote control (ref.045675) / Pedal (ref.045682):
The remote control enables the variation of current from minimum intensity (DC: 10A / MMA: 10A) to an intensity
defined by the user.
In this configuration, all modes and functions of the machine are accessible and can be set.
THERMAL PROTECTION & DUTY CYCLE
Thermal protection : when thermal protection is activated, cooling time is about 2 to 5 min depending on
external temperature.
Leave the machine connected to the supply after welding in order to let it cool down.
The welding unit describes an output characteristic of "constant current" type. The duty cycles following
the norm EN60974-1 (at 40°C on a 10mn cycle) are indicated in the table here below :
L = 2.5 x d.
L
D: Switch contact
C: Earth
B: Cursor
A: + 5V
Nb: The Potentiometer value must be 10 K
Ref.045699