Brochure

hartandcooley.com (800) 433-6341
RESIDENTIAL SERIES BLACK POLYESTER CORE
• Rated pressure per UL 181: 12" W.C. positive,
3
/
4
" W.C. negative (1/2" W.C. neg for 14" – 20" diameter)
• Recommended operating pressure:
6" W.C. positive for 12" diameter and under
4" W.C. positive for 14" diameter and over
• Rated maximum air velocity: 5000 FPM
• For residential and light commercial applications
COMMERCIAL SERIES
METALIZED POLYESTER CORE
• Rated pressure per UL 181: 16" W.C. positive,
1" W.C. negative (1/2" W.C. neg for 14" – 20" diameter)
• Recommended operating pressure:
6" W.C. positive for 12" diameter and under
4" W.C. positive for 14" diameter and over
• Rated maximum air velocity: 6000 FPM
• For residential and most commercial applications
COMMERCIAL SERIES
CORRUGATED ALUMINUM CORE
• Maximum rated pressure per UL 181:
12" W.C. positive for 10" diameter and under
8" W.C. positive for 12" diameter and over
3" W.C. maximum negative
• Rated maximum air velocity: 5000 FPM
INSULATION R-VALUES
Certified by Underwriters Laboratories Inc. and
the Air Diffusion Council in accordance with ADC
Flexible Duct Performance and Installation Standards
using ASTM C-518 at installed wall thickness on flat
insulation only
POLYETHYLENE JACKETS
A durable black polyethylene vapor barrier
High tensile scrim is used under the vapor barrier to
provide additional strength and tear resistance
Perm rating of 0.1 (ASTM E96 Method "A")
METALIZED JACKETS
A metalized polyester vapor barrier is constructed
by sandwiching fiberglass scrim between layers of
polyester to provide an outstanding combination of
strength and tear resistance
Perm rating of 0.04 (ASTM E96 Method "A")
SURFACE BURNING CHARACTERISTICS
(Class 1 Air Ducts)
Maximum flame spread: 25
Maximum smoke developed: 50
OPERATING TEMPERATURE RANGE
-20°F to 140°F continuous @ max. Pos. pressure
-20°F to 180°F intermittent @ 2" W.C. Pos. pressure
-20°F to 250°F intermittent @ 0.5" W.C. Pos. pressure
For corrugated aluminum cores:
-100°F to 250°F continuous @ max Pos. pressure
CODE APPROVALS, CERTIFICATIONS,
AND LISTINGS
UL 181 Listed NFPA 90A and 90B
IMC HUD
UMC
California Bureau of Home Furnishings
Most Federal, State, and Local codes and standards
Performance Data
3
Product Information
OUTSTANDING PERFORMANCE. All Hart & Cooley
flexible duct products are performance-tested in accordance
with industry standards to ensure reliability and years of
service. Our core is tested (in accordance with ADC FD 72-R1)
for actual installation static pressure/ temperature performance
and meets the ratings specified in our catalog. Our polyester
cores are also tested for microbial resistance by GEI per
ASTM D6329-98. The vapor barriers are tested for permeation
in accordance with ASTM test methods. Call-backs are
expensive and eat away at your profits. Use flexible duct you
know has been performance-tested.
INDUSTRY INVOLVEMENT.
Hart & Cooley is committed to the flexible
duct industry and supports it through
involvement in many industry-related
associations, committees, and organizations.
Participation in Air Diffusion Council and
Underwriters Laboratories, Inc. industry
advisory council allows Hart & Cooley to stay at the forefront of
industry changes.
MEMBER