Datasheet
5
REDUNDANT POWER SYSTEMS FOR H3C ENTERPRISE FIXEDCONFIGURATION SWITCHES
DC OUTPUT CABLES
DC OUTPUT CABLES FOR RPS500A3
H2*7
JD5
Cables coded 0404A03C, 0404A033, and 0404A08G all use H2*7 connectors. Cables coded 0404A03V and 0404A03U
use an H2*7 connector for direction B and respectively a JD5-A connector and a JD5 connector for direction A. (The
connector of direction A connects to the DC input socket of the switch, and The connector of direction B connects to
the DC output interface of the RPS unit.) A JD5-A connector looks like a JD5 except that a JD5 is a little bigger.
Cable type Code Output interface type Length
CAB-RPS-1m-3026C 0404A03C
D
irection A: H2*7 (4.20)
D
irection B: H2*7 (4.20)
1
m (3.28 ft.)
CAB-RPS Pwr-1m-H2X7 0404A033
CAB-RPS500/800-1m 0404A08G
CAB-Pwr-1m-PS3FP-I 0404A03V
D
irection A: JD5-A
D
irection B: H2*7 (4.20)
C
AB-Pwr-1m-PS3FP-II
0
404A03U
Direction A: JD5
Direction B: H2*7 (4.20)
DC OUTPUT CABLES FOR RPS1000A3
Cable type Code Powered device type Output interface type Cable length Maximum output current
CAB-RPS
PoE-2m-JD5
0404A053 PoE
Direction A: JD5
Direction B: JD5
2 m
(6.56 ft.)
25 A
CAB-RPS
Non PoE-2m-JD5-A
0404A054
Non-PoE
Direction A: JD5-A
Direction B: JD5-A
2 m
(6.56 ft.)
8A
CAB-RPS
Non PoE-2m-JD5
0404A055
Direction A: JD5-A
Direction B: JD5
2 m
(6.56 ft.)
8A
DC OUTPUT CABLES FOR RPS800A
Cable type Code Output interface type Length
CAB-RPS500/800-1m 0404A08G
Direction A: H2*7 (4.20)
Direction B: H2*7 (4.20)
1 m (3.28 ft.)
The RPS1000-A3 comes with three types of output cables, which are all default accessories, as listed. For each
cable, the connector of direction A connects to the DC input socket of a switch, while the connector of direction
B connects to a DC output interface of the RPS unit.