Manual Argos² 0572 Art. No. 0572 FB 04-278 Rev. 0 Date: 10.05.
Safety Instructions Foreword 3 Safety instructions Cleaning & Disinfection 4 8 Getting to know the unit 9 Before the use Area of Application Fill in the spray liquid Operation 10 10 10 11 Application Operation Work positioning Infilling the spray liquid Mounting/Changing the filter Insert the bur Adjusting the speed Spray Drying / changing tool Footswitch 12 12 13 15 15 15 16 16 16 16 Maintance and Care Changing the washer Changing the water filter Cleaning function Cleaning the chuck Maintance ov
Safety Instructions The Argos2 foot care unit was produced according to strict quality criteria and uses the latest technology in its design. The images in this manual may vary slightly from the product you have bought as we are constantly developing our products. This user manual includes a detailed description and explanation of how to use the Argos2 unit. If you have any questions or suggestions you can contact us by telephone or email. This user manual belongs with the Argos2 unit.
Safety Instructions Children should be supervised not to play with the appliance. The installation of the working area has to correspond to the relevant regulations. Set up the unit in such a way, that the louvers are not covered and the extracted air can escape well. To avoid the risk of an electric shock, this device might only be connected to a power supply with protective conductor. If you pull the power plug it will stop the connection to the mains power supply.
Safety Instructions nique. Wear a nose and mouth protec-tion. Always follow the safety instructions provided by the manufacturer of the materials being formed. For safety reasons you must always wear disposable gloves and protective glasses when operating this unit. In addition, a face mask conforming to EN 14683 type IIR or EN 149 FFP 2 must also be worn. When changing the filter it is advisable to wear a face mask conforming to EN 14683 type IIR or EN 149 FFP 2.
Safety Instructions Rinse the tank daily and fill it with fresh water every day. Empty the unit if it is not in use for a longer period of time (e.g. before vacations). Clean out the tank. Set the spray function on maximum. Now start the spray function, and the water will spray for approx. 3 min. The fluid will be blown out of the complete spray system and handpiece. Ensure that the patient’s foot and the handpiece are held firmly in place during the operation.
Safety Instructions Switch off the unit immediately if: the bur comes off during the treatment itself. the motor blocks during the treatment. Always follow the operating instructions. Do not carry out any repairs, modifications or maintenance work yourself. This is only to be accomplished by an authorized specialist. The mains cable may also only be changed by the manufacturer or an authorized specialist. Maintenance records may be supplied to repair workshops and trained technicians upon request.
Cleaning and disinfection Cleaning and disinfection The device is designed to be compatible with rotating instruments which do not penetrate the skin or mucosal or inadvertently may still cause injuries. For this application please adhere to the cleaning and disinfection instructions provided below. After every treatment please carry out these steps: Remove the rotating tool (e.g. bur) first. To do so, pay attention to the instructions of its manufacturer.
Getting to know the unit 1 7 1 2 3 4 5 6 7 8 9 10 11 12 13 14 2 3 4 8 9 10 11 12 13 5 6 14 Display Knob to start the suction and for adjusting the suction level Knob for adjusting the amount of spray Connection for suction hose Lid of the water tank Water tank ON / OFF button (line voltage is not disconnected, unit in standby) handpiece speed down handpiece speed up Switch for modus change (spray or suction) Switch for turning ON/ OFF the handpiece/ spray Switch for changing running direction of t
Before the use Do not exceed the maximum level when filling the tank. Please read through the instructions carefully before using the unit and carefully note the safety advice. Always keep this manual accessible to any users of the drill. While screwing back the cover on the tank, make sure that is closed correct. Otherwise there will no pressure be build up. Put the tank back in the housing. Area of application This device should only be used by people who have completed a foot care qualification.
Before the use If you have a foot switch insert its plug into the port on the right of the device which displays this sym- Operation The working area must conform to the conditions described. Set up the unit in such a way, that the air slits are not blocked and the extracted air can escape well. To guarantee unhindered air flow there must a gap of at least 12cm to the right of the device.
Application After setting the speed and the spray amount or suction, you can start with working. Operation In the following section the order in which you should use the device is described. Additionally the individual steps will be explained in detail. Read the complete manual before use. If you want to take a break or finish the job press the standby button (7). The handpiece motor and suction/spray will turn off. The handpiece can now be placed in its holder on the right of the unit.
Application Work positioning The following images are examples of how to work on various parts of the foot. Always make sure that the foot is firmly gripped and that you can work freely and without strain.
Application 14
Application Infilling the spray liquid Mounting/Changing the filter Switch off the device. Pull out the spray tank on its handle. Hold the cover of the tank in hand and unscrew the tank. Now fill it with distilled water and anti germ liquid (e.g. AQUAHY item no. 8555). Remove cover plate with filter (Art.5115). Now the filter can be pulled from the plate and be changed. Never work with full filter or without filter. Put up cover plate. The cover plate must lie flat but may move a little.
Application back completely into the tank from the hoses. With this process, a bubbling can be heard in the tank. Drying/ Changing Tool Press key (11) and the handpiece and spray will be turned off. Now only air will come out of the top of the handpiece, which you can use to dry the spot of the recent treatment. When you push button (11) again, the spray and handpiece are working again. Hint: This function can also be used to change your tools while the handpiece is not running. Foot switch (Art.
Maintenance & Care Washer The top of the handpiece is equipped with a white washer (article no. 4571). This washer has to be replaced by a new one every four weeks, unless exchanging it, water could enter the handpiece and cause a lot of damages of the internal parts. Exchanging the washer Screw off the top of the handpiece. Pull out the washer with some tongs. Look for little parts of the washer in the top and around, if you find some, remove such eventually.
Maintenance & Care Cleaning the chuck Cleaning function Because of the washer, very little dirt might enter the handpiece. In the curse of the time, dirt can appear and might interrupt the performance of the handpiece. Therefore clean the chuck monthly. Use the cleaning function, if the nozzle is blocked. Turn the unit off. Remove the water filter at first. (For its instructions see paragraph above). Fill the tank with distilled water. Close the tank and put it back into the unit.
Maintenance & Care Set the first key (see picture below) on the axle and hold it tight. Screw out the chuck with the second key, which has the forefront. Maintance overview What has to be done? Cleaning the chuck, changing the washer 4571 Changing the washer 4571 Changing filter 3497 Maintenance by repair workshop (Changing worn parts; checking motor brushes, housing; Cleaning; check leakage current) The assembly of the clamping device takes place in reverse order.
Handling Instructions Always deposit the handpiece with the top downwards. Therefore you can avoid liquid from entering the handpiece. Only work with tools, which are flawless. Do not work with tools which - are bent or out of balance - whose shaft is worn out or - are rusty. Never put the handpiece into any kind of liquid, and never oil or grease the handpiece. Clean its surface with a damped cloth. Pay attention, that no moisture or liquid enters the handpiece. Never use spray dis-infection.
Troubleshooting Handpiece vibrates, is very noisy and/ or becomes warm in the front part Use of bent burs/ tools Use a different bur/ tool to test this. The bur/tool itself can be tested with the hadewe Bur Shaft Tester (Art. No. (4990) to see if it is bent). It does not spray Pressure cannot be set up in the tank, because the lid is not tightened well. There are parts of dirt in the spray system cleaning the spray system according to page 10. The blue water filter (art. No.
Troubleshooting HS, EE in Display The motor does not start, because thechuck is still open Insert the bur and tighten it well (pull the black buttonbackwards).Than start the handpiece at max. speed. Spray stream stutters There is air in the spray system. After 5 min running, this effect will disappear. Acceleration of the spray stream Note: To reduce the starting time of the spray, turn the spray regulator on Max. After the spray started, adjust the stream to the requested amount of water.
Techniqual Details 0572 Argos² Total weight: 5,6kg Dimension: W314xH135xD223mm Power supply: 230V, ~, 50-60Hz Pmax: 300 W fuse primary: F1/F2: 500 mA delay action fuse F3/F4 3,15 A delay action fuse Fuse Sec. Thermo fuse Protection class I Accuracy of speed display: ±10% Ambient conditions: The device is intended for use in dry, closed rooms. Operation: Temp.: +10 °C to +26 °C Rel. humidity: 25% to 75% (not condensed) Air pressure: 700 hPa to 1060 hPa Storage: Temp: -5°C to +55°C Rel.
Techniqual Details Symbol Caution! Keep dry Important Note! Alternating current Follow instructions for use Direct current Safety fuse ON/ OFF button (standby) (no disconnection from main power supply) Type B applied part Socket foot switch Handpiece speed up Date of manufacture Handpiece speed down Disposal The device and filter may contain infectious material such as residual sanding dust or skin particles. Therefore please bear in mind the following disposal instructions.
Techniqual Details Safety Check A safety check must be done compliance with the regulations the country where the device used. The inspection interval once a year. Accessories in of is is Art. No.
hadewe GmbH Grambartstraße 10 30165 Hannover Germany info@hadewe.de www.hadewe.