Monitoring System Installation & Operation TRM6.1, TRM6

TRM6.1
Free Field Frequency Response 55Hz21kHz, ±2dB
Peak Acoustic Output 119dB (per pair w/music @ 1m)
Total Harmonic Distortion (THD) <0.5%, 150Hz21kHz (90dB @ 1m on axis)
High Frequency Driver 1" (25mm) Vifa Soft Dome
Low Frequency Driver 6.5" (165mm) Polypropylene Cone/
Inverted Nitrile Rubber Surround
Magnetically Shielded
Cabinet 0.26 ft
3
(7.3 liters) Vented
Front Panel: Power Switch
System LED (Power/Clip/Thermal)
Rear Panel: XLR Balanced Input
RCA Unbalanced Jack
Unbalanced/Balanced DIP Switch
Input Sensitivity DIP Switches
Bass Rolloff DIP Switches
Bass Shelving DIP Switches
Treble Shelving DIP Switches
IEC Standard Line Input / AC Line Fuse
Dimensions 8.875"W x 13.25"H x 11.50"D
(22.54cm x 33.65cm x 29.21cm)
Net Weight 23 lbs. (10.43kg)
AMPLIFIER SECTION
Power Rating FTC (20Hz20kHz, 0.1% THD)
35 Watts RMS @ 6 ohms (high frequency)
50 Watts RMS @ 4 ohms (low frequency)
Signal-to-Noise >100dB
CMRR >70dB typical @ 1kHz
Input Impedance 47k per phase balanced, 47k unbalanced
Input Sensitivity Range 500mV to 3V (unbalanced)
275mV to 1.5V (per phase balanced)
(+4dB, +1dB, -2dB, -5dB, -8dB, -11dB)
Gain +33dB max. to +18dB min.
Power Consumption Idle Power: 11W / 150mA @ 115 VAC
(both channels driven) Idle Power: 11W / 75mA @ 230 VAC
Normal Operation: 55W / 600mA @ 120 VAC
Normal Operation: 54W / 310mA @ 230VAC
Full Power: 139W / 1.37A @ 120VAC
Full Power: 130W / 680mA @ 230VAC
CROSSOVER SECTION
Crossover Frequency 3.2kHz
Crossover Slope 24dB/octave Linkwitz-Riley
Subsonic Filter Selectable 30Hz or 60Hz @ 12dB/octave
Bass Shelving 30Hz to 200Hz, ±4dB
(+4dB, +2dB, 0dB, -2dB, -4dB)
Treble Shelving 5kHz to 20kHz, ±4dB
(+4dB, +2dB, 0dB, -2dB, -4dB)
PERFORMANCE SPECIFICATIONS
i
Specifications are subject to change without notice.
Frequency Response
@ 1m on axis
Horizontal Polar Response
Energy Time Curve
Dimensions